6. Set the Duration of Sound (1 – 100 sec) to determine how long the *.wav file will play
7. Configure the Area Alarm Setting for the selected detection zone by selecting one of the following conditions:
a. In the Condition drop-down menu, choose any to trigger an alarm every time human/vehicle/object presence is
detected in the defined area.
b. In the Condition drop-down menu, choose “=” (equal to) in the drop-down menu and enter the desired number
of persons/vehicles/objects. This way the alarm will be triggered only if the specified number of persons/vehicles/ob-
jects is met in the defined area.
jects is met in the defined area.
c. In the Condition drop-down menu, choose “>=” (greater or equal to) in the drop-down menu and enter the
desired number of persons/vehicles/objects. This way the alarm will be triggered only if the specified number of
persons/vehicles/objects is met or exceeded in the defined area.
persons/vehicles/objects is met or exceeded in the defined area.
3.23.3.2. Configuring CrossWire alarm
The CrossWire alarm detects any human/vehicle/object that is crosses the specified boundaries in a predetermined direction
and initiates an alarm.
and initiates an alarm.
Please note that the CrossWire alarm option will not be available for the overhead-mounted cameras and in the crowded
locations.
locations.
Note
Due to the background registration tech-
nique the persons, who remain in the same
position, without moving, for an extended
period of time will not be detected.
nique the persons, who remain in the same
position, without moving, for an extended
period of time will not be detected.
To configure CrossWire alarm, do the following:
1. Choose CrossWire in the Alarm menu
2.
Choose the CrossWire
drawing tool
3. Draw the detection zone in the live-view window. A total of three CrossWire detection alarm zones can be drawn.