 Installation 
Connecting the Servers
Connecting the servers:
6.  
Power on the KVM devices, in any order. You will see the port LEDs flash 
on and off and the seven-segment LEDs will light up, displaying a series 
of diagnostic codes, eventually stopping with the digits “XX”, where XX is 
its BANK address.
NOTE: If the KVM devices still do not enumerate with their corresponding BANK 
addresses, check that all KVM devices have the correct BANK address assigned 
to them and that all Daisy-Chain Cables are connected properly.
7.  
If the primary BANK is set to address 00, the KVM administrator must 
configure the Rack-Mount Console KVM Switch for daisy-chain usage. To 
do this, take the following steps: (
NOTE: You may see lines across some of 
the consoles, which is normal. This is an invalid configuration, which can be 
eliminated by activating the “Daisy-Chain this Switch” option.) 
a)
  
Open the OSD by pressing the “Scroll Lock” key twice, then the 
space bar, and enter “Setup”.
b)
  
Go to the “Options” page, and select the “Advanced” button.
c)
  
In the “Advanced” dialog, check the “Daisy-chain this KVM” box.
d)
  
A dialog will appear informing you that, “This will reset the KVM 
switch to change this setting.” Click “OK” to clear the dialog and 
automatically power-cycle the Rack-Mount Console KVM Switch. 
When the Rack-Mount Console KVM Switch reboots, it will interact 
with the remainder of the other daisy-chained KVM devices as 
expected. You can verify this by opening the OSD and scrolling 
through the list of servers; if any of the other KVM devices appear  
in BANK 00’s list, then the Rack-Mount Console KVM Switch is 
working properly.
NOTE: If you don’t configure BANK 00 for use on the daisy-chain, then the  
Rack-Mount Console KVM Switch will not be able to interact with any of the 
other KVM devices, and vice versa. In addition, the unit’s front panel will not 
act the same as the other units’ front panels. Finally, there could be some 
unpredictable interactions caused by connecting an improperly configured  
BANK 00 to a daisy-chain.