WARNING
:
Be extremely careful when removing the lamp housing. In the 
unlikely event that the bulb ruptures, small glass fragments may be 
generated. The lamp housing is designed to contain these frag-
ments, but use caution when removing the lamp housing. Before 
replacing the lamp, clean the lamp compartment and dispose of 
cleaning materials. Wash hands after lamp replacement.  
Hg – Lamp contains mercury. Manage in accordance with 
local disposal laws. See www.lamprecycle.org.
5
Detach the lamp connector from the projector by depressing the locking 
tab on the connector and lightly pulling it free.
6
Loosen the captive screw that attaches the lamp housing to the projector. 
Carefully remove the lamp housing. Dispose of the lamp in an environ-
mentally proper manner. 
7
Install the new lamp housing and tighten the screw.
8
Re-attach the lamp connector to the projector. The locking tab should 
engage when the connector is fully plugged in.
9
Replace the lamp door by sliding it into place. Be sure the lamp connec-
tor wires are not in the way.
10
Plug in the power cord and press the Power button to turn the projector 
back on.
11
To reset the lamp hour timer, navigate to the Settings>Service menu 
and select Reset Lamp Hours. See page 33 for details. 
squeeze lamp connector
loosen screw
Service menu