11. PROTECTION OPERATION LIST
 Failure
Protection
Operation Indicator
Remedy
Recovery
Overcurrent due 
to overload
Current limiter activated 
when impedance drops 
below the specified 
value. 
Peak indicator lights.  Remove overload.
Connecting a correct load 
automatically restores 
normal operation. 
Short circuit
Current limiter activated. 
Load is disconnected.
Protection indicator 
lights. 
Check speakers 
and lines for short 
circuit.
Temperature rise
at power amp.
heat sink 
(over 110°C or 230°F)
Load disconnected.
Protection indicator 
lights.
Temperature rise 
inside the unit 
(over 80°C or 176°F)
Built-in amplifier unit 
that caused the failure 
halted.
Four indicators of 
the corresponding 
channel extinguish.
Check the unit for 
correct ventilation 
and overload. 
Operation automatically 
returns to normal when 
the temperature decreases.
Abnormal DC 
 voltage output
Load disconnected.
Protection indicator 
lights.
Contact the TOA dealer where the unit was 
purchased.
Turn off this unit's Power 
switch. Correct the load, 
then turn on the power.
12. TAMPER-PROOF CAP ATTACHMENT
To protect the input level control from accidental operation, it is recommended to replace the control knob with
the supplied tamper-proof cap as illustrated.
Input level control
Tamper-proof cap (accessory)