Cma -44l Hardware Manual

Page of 26
 
                                                                                            
Parts Manual
 
 
 
QTY
P/N
DESCRIPTION
12 FT 
00400.00
Conduit 3/8 sealtite
2 1 
00401.00
ST-3/8 
straight connector
3 1 
00402.00
ST-90 
deg.3/8 connector
4 2 
00446.00 
Fork 
tongue connector
24 FT 
00529.00
Wire 18 gauge black
6 1 
13427.60
Template kit
7 1 
13427.61
Mounting bracket
8 1 
13427.62
Actuator
9 1 
13427.63
Bumper
10 2 
03817.00
6-32 
wing nut
11 
03814.10
Lock star washer
12 
00914.10
1/4-20 x 5/8 hexhead bolt
13 2 
00968.00
1/4 
split lock washer
14 
00924.00
1/4 ss washer
15 2 
00912.00
1/4-20 
nylon lock nut
16 1 
13427.10
Limit 
switch
Instructions: 
1.  Determine the approximate centerline of the dish rack as it travels down the 
clean table. 
2.  Place the template from the template kit (6) with the lower edge resting on the 
table surface, against the end roll, and centered along the dish rack’s line of 
travel.  Mark the positions of the four holes and follow up with a center 
punch.  
3.  Drill a 1/8” hole through each position .The upper two holes then drilled out 
to1/2”. 
4.  Fasten the template with two bolts and nuts from the template kit (6).The  
lower holes then drilled out to 3/8”. 
5.  From the outside, place the mounting bracket (7) halfway through the 3/8” 
lower holes on the table and the hinged actuator (8) through two 1/2” upper 
holes in the table. 
6.  Secure the bumper (9) by tightening the two bolts (12) with lock washers (13) 
through the two holes in the actuator. 
7.  Push the mounting bracket all the way into the holes in the table and tighten it 
with two lock nuts (15) and two washers (14).  
8.  Attach the conduit (1) between the control box and the table limit switch (16).  
Run two wires (5) through the conduit and conduit connectors (2,3), and 
attach one to the COMMON terminal on table limit switch, and the other to 
the normally OPEN terminal, using two fork tongue connectors (4).  Secure 
the table limit switch on the mounting bracket with two wing nuts (10).  
Remove jumper from the optional table limit switch connection in the control 
box (see note 1 of the wiring diagram). Then, attach the other ends of the two 
wires to the terminal block (it does not matter which table limit switch wire 
you attach to either terminal because it is only a loop).  
 
 
MODEL CMA-44 Part Manual rev. 2.16   02/12/08                                                                                           Page 
26