Epson LQ-1050 User Manual

Page of 222
ESC ( -
Select/Cancel Score
Format :
ASCII code:
ESC ( 
         
Decimal:
27 40 45     m   
Hexadecimal: 1B 28 2D 
   m 
 
Comments:
Use decimal or hexadecimal values for all variables, not ASCII
characters.
Use the following values for the first 3 variables:
 must be 
3
 must be 0
m must be 1
The value of 
 determines the location of the score:
 = 1 for underline
 = 
for strikethrough
 = 3 for overscore
The value of 
 determines whether the score line is single,
double, broken, or continuous:
 = 0
Cancel the score line selected by 
d1
 = 1
Single continuous line
 = 
2
Double continuous line
d2= 5
Single broken line
 = 
6
Double broken line
The last three bits of 
 determine the characteristics of the score
line as shown below:
Bit 2
Bit 1
Bit 0
On (1)
Broken
Double
Single
line
line on
line on
Off (0)
Continuous
Double
Single
line
line off
line off
Notes: If Bit 1 and Bit 0 are both off, the selected score is
cancelled. Double line and single line scores cannot be
combined at the same score position.