GE pgp989snss User Manual
Dimensions and Installation Information
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
service,
800.626.2000.
Listed by
Underwriters
Laboratories
PGP989SN
GE Profile
™
30" Downdraft Gas Cooktop
22
7
⁄
16
ʺ
(22
9
⁄
16
ʺ SS)
20
1
⁄
2
ʺ
22ʺ
29
7
⁄
8
ʺ
(30ʺ SS)
2
3
⁄
16
ʺ
(2
1
⁄
4
ʺ SS)
28
3
⁄
4
ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
Note: A 5" minimum spacing to adjacent side wall is required
Specification Revised 4/09
230285
*Note: A 5" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Wall Installation: Wall installations require 25”
countertop depth. When cabinet is flush against
the wall, the fan housing can be rotated to the
horizontal position for direct venting through
rear wall. Make a countertop cutout in the
range cabinet according to unit dimensions
and installation type. Duct hole is positioned in
back of cabinet for through-the-wall ducting.
Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/
islands a minimum 26” countertop depth is suggested.
Blower should be in vertical position. Island or
peninsula cabinets may require adjustment in cutout
depth and/or location within the width dimensions.
Duct hole is positioned in bottom of cabinet for island
or peninsula installation.
Slab Installation: For peninsula or island installation
and rear wall ducting,
countertop depth. When cabinet is flush against
the wall, the fan housing can be rotated to the
horizontal position for direct venting through
rear wall. Make a countertop cutout in the
range cabinet according to unit dimensions
and installation type. Duct hole is positioned in
back of cabinet for through-the-wall ducting.
Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/
islands a minimum 26” countertop depth is suggested.
Blower should be in vertical position. Island or
peninsula cabinets may require adjustment in cutout
depth and/or location within the width dimensions.
Duct hole is positioned in bottom of cabinet for island
or peninsula installation.
Slab Installation: For peninsula or island installation
and rear wall ducting,
6” PVC duct or locally
approved piping should be used if installing under
a poured concrete slab.
Installation Information: Before installing, consult
installation instructions, packed with product, for
current dimensional data.
Note: These cooktops are approved for indoor use only.
Installation Information: Before installing, consult
installation instructions, packed with product, for
current dimensional data.
Note: These cooktops are approved for indoor use only.
20
9
4
10-1/2
16
C
L
Cabinet Dimensions (in inches)
22
7
⁄
16
ʺ
(22
9
⁄
16
ʺ SS)
20
1
⁄
2
ʺ
22ʺ
29
7
⁄
8
ʺ
(30ʺ SS)
2
3
⁄
16
ʺ
(2
1
⁄
4
ʺ SS)
28
3
⁄
4
ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
Note: A 5" minimum spacing to adjacent side wall is required