Navitar 10k User Guide

Page of 20
7
Operation
Operating and Turning Off the 10K Projector
1. Plug the unit in to the correct fixture. The software version of the device will
show up on the display panel for about 5 seconds. Now the projector is in the
Stand-by-mode which is confirmed by a red LED next to the On/Off button.
2. Press the On/Off button for one second to put the projector in operating mode.
On the display you will see the current slide number in the slot which was zero
after switching the projector on.  You can easily adjust the Slide and Focus with
the + and - buttons. Please try the settings to get a feeling for the simple
functions of changing a slide and how to set the focus.
After starting the projector, the lamp should be on for approximately 5 minutes
before the projector can be switched off. If you do not observe this, the life-
duration of  the lamp will be dramatically shorter. In order to avoid this, a small
safety feature is built into the projector:
During this 5 minutes period, a red LED on the control panel will blink. This
reminds you, that the projector cannot be turned off or on for 5 minutes.
3. To turn the projector off, please press the On/Off button for one second. The
lamp will switch off and the projector will run for approximately 3 minutes in the
cooling mode.  After the cooling period the projector will turn off automatically.
When turned off the projector automatically proceeds to the zero positions so
that the tray can be removed easily.
Proper Ventilation
Good ventilation is absolutely necessary for the operation of the projector and the
safety of the slides. Proper ventilation is obtained when the projector gets sufficient
fresh air through the ventilation openings on the side and in the back of the projec-
tor.  Do not block these ventilation openings.  In rooms with high temperatures,
or in projection cabinets, air-conditioning is advisable.
Operating at a Tilt Angle
The Navitar SUPERNOVA 10K has
adjustable legs to allow for projection at
various  locations.  The projector can be
set to an angle of up to 30°.  To get a
larger angle, the projector legs can be
propped up on pieces of wood or other
sturdy material.  You should observe that
the keystone correction is compensated
by moving the screen to a certain angle.
ATTENTION:
The 10K uses a metal halide lamp requiring a minimum burning time of at least 5 minutes. If you do not
observe the minimum burning time the life-duration of the lamp will be considerably shortened.  A
general advice is to ignite the lamp only when necessary to guarantee a long life-duration for your lamp.
Frequent ignition shortens the life-duration of the lamp.