Sony fwd-50px3 Manual

Page of 28
1
FWD-50PX3
1. Communication Parameters
Communication method
RS-232C
Synchronous method
Asynchronous
Baud rate
9600bps
Character length
8bit
Parity
None
Start bit length
1bit
Stop bit length
1bit
Flow control
None
2. Pin Assignment
1
2
3
4
5
Monitor side (D-sub 9-pin)
_
 External view 
_
6
7
8
9
1
2
3
4
5
6
7
8
9
Host side (D-sub 9-pin)
_
 External view 
_
Pin No.
Function
1
NC
2
TXD
3
RXD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC
Pin No.
Function
1
NC
2
RXD
3
TXD
4
NC
5
GND
6
NC
7
NC
8
NC
9
NC
3. Communication Data Format
(a) Control message
No.
Item
Value
1
Header
0x8C: Control
2
Category
0xXX
3
Function
0xXX
4
Data1 (Length)
0xXX
5
Data2 (Data1)
0xXX
:
:
0xXX
:
:
0xXX
X
DataX
0xXX
X
+
1
Check Sum
0xXX
*
Check Sum: Sum total of 1 to X. Lower one-byte data is validated when a
value exceeds 255 (1byte).
*
Set the command interval to 500 ms or more when transmitting the
Control command continuously.
*
Set the command interval to 500 ms or more when transmitting the same
command (Enquiry) after the Control command.
(b) Enquiry message
No.
Item
Value
1
Header
0x83: Enquiry
2
Category
0xXX
3
Function
0xXX
4
Data1
0xFF
5
Data2
0xFF
6
Check Sum
0xXX
*
Check Sum: Sum total of 1 to X. Lower one-byte data is validated when a
value exceeds 255 (1byte).