There is usually no need to defrost the refrigerator, because the ice deposited on the inner
back wall is automatically defrosted. Ice deposits on the inner back wall during
compressor operation; later on, when the compressor is not operating, the ice defrosts and
water drains through the outlet in the inner back wall into the drain pan situated above the
compressor where it evaporates. If you see water building up in the rear of the unit,
check that the drain trough is not clogged. Use a pipe cleaner or a piece of flexible wire.
During extremely hot and humid weather some ice may build up. If necessary, remove
contents of the refrigerator, turn the thermostat to 0 and allow defrosting. A hair dryer
may facilitate the process.
back wall is automatically defrosted. Ice deposits on the inner back wall during
compressor operation; later on, when the compressor is not operating, the ice defrosts and
water drains through the outlet in the inner back wall into the drain pan situated above the
compressor where it evaporates. If you see water building up in the rear of the unit,
check that the drain trough is not clogged. Use a pipe cleaner or a piece of flexible wire.
During extremely hot and humid weather some ice may build up. If necessary, remove
contents of the refrigerator, turn the thermostat to 0 and allow defrosting. A hair dryer
may facilitate the process.
INSTALLING THE CLEANING KIT
Read and understand the following instructions before installing the cleaning kit.
1. Mix one gallon of warm water and one ounce (one tablespoon) of cleaner in a bucket.
Note: Do not use lye, soap or hot water.
2. Remove the cleaner cap. Fill the jar and replace the cap. Leave the remaining solution
in the bucket
3. Turn off either the air cock on the regulator or the valve on the CO
Note: Do not use lye, soap or hot water.
2. Remove the cleaner cap. Fill the jar and replace the cap. Leave the remaining solution
in the bucket
3. Turn off either the air cock on the regulator or the valve on the CO
2
tank.
4. Disconnect the tap from the barrel. Then disconnect the beer line from the tap by
turning the nut counterclockwise. Place the tap and end of the hose in the bucket.
5. Remove the faucet form the tower with the wrench and attach the fitting on the
cleaning bottle in its place.
Note: Make sure there is a washer in the back of the fitting.
6. Hold the cleaning jar upside down until the solution runs through the system into the
bucket
7. Fill the jar with cold clean water and repeat the process until the water runs clean.
8. Rinse the tap in the bucket with cold water
9. Remove the fitting from the tower and reinstall the faucet. Make sure the washer is in
the back of the faucet
10. Re-attach the beer hose to the tap and attach the tap to the barrel.
Note: Beer lines should be flushed after each keg is emptied.
CLEANING THE APPLIANCE
Disconnect the power supply before cleaning the appliance.
Do not use coarse or abrasive cleaning agents as you can damage the surface.
Do not use coarse or abrasive cleaning agents as you can damage the surface.