Syswan sw24 User Manual

Page of 114
Syswan Duolinks SW24 Series 
 
Page 8
 
User Guide
 
© Syswan Technologies, Inc. 
 
WAN 
LINK/ACT 
 
10M/100M 
 
ON – Physical connection to the Broadband modem on WAN port 1/2 established. 
OFF – No physical connection on WAN port 1/2. 
ON – Physical connection using 100BaseT on WAN port 1/2 established. 
OFF – 10BaseT connection or no connection on WAN port 1/2. 
System 
Power 
 
Status 
 
 
OFF – No power. 
ON – Normal Operation 
OFF – Normal operation. 
ON – Firmware not loaded or Hardware error. 
Blinking – Data in/out 
 
 
Some Status and Error conditions are indicated by combinations of LEDs, as shown below 
 
LED Action 
Condition 
WAN1 LINK/ACT & 10M/100M LEDs flash alternatively. 
Firmware Download in progress. 
WAN1 LINK/ACT & 10M/100M LEDs flash concurrently. 
MAC address not assigned. 
WAN1 LINK/ACT & 10M/100M LEDs solid On. 
SDRAM error. 
WAN2 LINK/ACT & 10M/100M LEDs solid On. 
Timer/Interrupt error. 
LAN1 LINK/ACT & 10M/100M LEDs solid On. 
LAN/WAN error. 
 
If your discover any of the above error conditions, please contact our support team for assistance.