Bushnell 20-0750 Owner's Manual

Page of 2
Y A R D A G E   P R O
®
Your  YA RD AGE  PRO
®
750 is  a  prec i s ion  instrument  designed  to
provide many years of enjoyment.  This boo k l e t will help you achieve optimum performance by
explaining  its  adjustments  and  features  as  well  as    how  to  care  for  this  fine  instrument.  To
ensure  optimal  performance  and  lo n g e v i ty,  please   read  these  instructions  before  using  yo u r
YA RD AGE  PRO
®
750 .
I N T R O D U C T I O N  
The YA RD AGE PRO
®
750 emits invisible, eyesafe, infrared energy
pulses.  Sophisticated  circuitry  and  a  high  speed  clock  are  used  to
i n s t a n t a n eously  calculate  distances,  by  measuring  the  time  it  takes  for  each
pulse to travel from the rangefinder, to the target, and back .
The  ranging  ac c u r acy  of  the  YA RD AGE  PRO
®
750  is  plus  or  minus
one  yard  /  meter  under  most  circumstances  (see  description  of  “Pr ec i s io n ”
indicator  below).    The  maximum  range  of  the  instrument  depends  on  the
r e f l ec t i v i ty  of  the  target.  The  maximum  distance  for  most  objects  is
750  yards  /  meters  while  for  highly  reflective  objects  the  maximum  is
999  yards  /  meters.    Note:  You  will  get  both  longer  and  shorter  maximum
distances  depending  on  the  reflective  properties  of  the  particular  target  and
the environmental conditions at the  time the object is being distanced to.
The color, surface finish, size and shape of the target all effect reflec t i v i ty and
range.   The brighter the  color,  the longer  the range.   Red  is  highly  reflec t i v e ,
for example, and allows longer ranges than the color black, which is the least
r e f l ective color.  A shiny finish provides more range than a dull one.  A small
target  is more  difficult  to range  than a  larger target.   The angle  to the target
also has an effect.  Shooting to a target at a 90 degree angle (where the target
s u r f ace  is  perpendicular  to   the  flight  path  of  the  emitted  energy  pulses)
provides  good  range  while  a  steep  angle  on  the  other  hand,  provides  limited
ranging. In addition, lighting conditions (e.g. the amount of sunlight) will affec t
the  ranging  capabilities  of  the  unit.  The  less  light  (e.g.  overcast  skies)  the
f a rther  the  unit’s  maximum  range  will  be.  Conversely,  very  sunny  days  will
d ecrease the unit’s max imum range.
O P E R A T I O N A L   S U M M A R Y  
While  looking  through  the
mo nocular, depress the fire button (see Figure 1) (top right hand side of unit)
once to activate the inview display system (LCD).  Aim the YA RD AGE PRO
®
750
at a target at least 21 yards away, depress and 
hold the fire button down
until range reading  is displayed.  Release the fire button.  Note:  O n c e
a ctivated, the YARDAGE PRO
®
750’s LCD will remain active and display the last
distance measurement for  30 seconds. You  can depress  the  fire button  again
at  any  time  to  distance  to  a  new  target.  As  with  any  laser  device,  it  is  not
recommended  to  directly  view  the  emissions  for  long  periods  of  time  with
magnified lenses.
F E A T U R E S  
The  YA RD AG E  PRO’s  sophisticated  circuitry  allows  you  to
s e l ect between various units of measure and targeting modes. In addition, yo u r
YA RD AGE  PRO’s LCD incorporates illuminated indicators that advise you when
the  laser  is  active,  what  the  quality  level  (a  measure  of  reflec t i v i ty)  of  the
target  is,  what  the  prec i s ion  tolerances  of  a  specific  measurement  are  and  when  the  battery
charge  is  low (see Figure 2).  A summary of these features is presented belo w :
U n i t   o f   M e a s u r e   O p t i o n s
The  YARD AG E  PRO
®
750  can be used  to measure
distances  in  yards  or  meters.    The  unit  of  measure indicators  are  located  in  the  lower  right
p o rt ion of the LCD.  To select between yards and meters look through the  mo nocular, depress
the  “mode“  button  (see  Figure  3)  (lower  right  hand  side  of  the  unit)  and  hold  it  down  for
approximately  5  seconds.    If  you  are  changing  from  yards  to  meters,  a  change  in  unit  of
measure will be indicated by the illumination of the ME T ER indicator while the YA R D indicator
is  turned  off.    If  you  are  changing  from  meters  to  yards,  the  opposite  will  occur.    Note: T h e
YARDAGE PRO
®
750  will return to the last setting used, each time the unit is turned-on.
T a r g e t i n g   M o d e s
S TAN D AR D ( LCD  Indicator    -    none)  –  This  setting  allows  most  targets  to  be  distanced  up  to
75 0 yards. Used for moderately reflective targets that are typical of most distancing situations. 
S C A N ( LCD Indicator   -  “SCAN”)  – This mode allows the range to be continuously  updated for
10 seconds when the fire button remains depressed. It can be used to scan an area containing
several  objects  or  a single object that is moving. Note: Objects further away require  a slower
scanning  pace  than  objects  at  a  closer  distance.  The  minimum  distance  in  this  mode  is  the
same as in  the standard mode.
I l l u m i n a t i n g   I n d i c a t o r s
A C T I V E   L A S E R ( LCD Indicator -  “LASER”) – Located in the upper le ft port ion of LCD .  Wh e n
illuminated, indicates that energy pulses  are being emitted  from unit.
T A R G E T   Q U A L I TY   G A U G E ( LCD  Indicator    -    “TA RGET  QU A L I TY”)  –  Located  in  the  upper
middle  port ion  of LCD.    Gauge indicating  amount  of energy  pulses  being  received back from
the  target.    Gauge  is  calibrated  to  fill  squares  from  left  to  right.    The  higher  the  number  of
returning energy pulses, the greater the number of squares that will fill with illumination.  Th i s
gauge  can  be  used  to  scan  ac r oss  a  target  that  is  difficult  to  acquire  to  find  the  mos t
r e f l ective point for ranging (see  Trouble Shooting Ta b l e ) .
P R E C I S I O N   P A R A M E T E R   I N D I C A T O R ( LCD Indicator  -  “PRE CISION”) –
When illuminated, indicates the distance measurement is within plus or minus 1
yard or meter.  If it is not illuminated after obtaining a measurement, the distance
measurement is within plus or minus 3 yards or meters.
L O W   B A T T E R Y   C H A R G E ( LCD  Indicator    -    “BATT”)  –  When  illuminated,
indicates the  battery charge is low and battery should be  replac e d .
R o l l   D o w n   E y e c u p
The  YA RD AG E  PRO’s  mo nocular  is  equipped
with  a  rubber  eye cup  designed  for  your  comfort  and  to  exclude  extraneo u s
external  light.    If  you  wear  sun  /  eyeglasses,  roll  down  the  eyecup.    This  will
bring your eye closer  to the ocular lens, thus providing improved field of view.
S P E C I F I C A T I O N S :
O p t i c a l   D e s i g n
The  YA RD AGE  PRO
®
750  features  a  Perma  Foc u s
®
mo nocular optical system for viewing your target.  A liquid cry s t al display (LCD) is
mounted  within  the  optical  system  and  when  activated,  displays  a  reticle  for
ta rgeting, yard / meter a nd mode designations, a target qualit y gauge , as well as
p r ec i s ion  and  low  batter y  indicators.  Inherent  in  the  manufacturing  process  are
small  black  spots  that  appear  in  the  optical  system.  These  are  a  natural
ch a r acteristic of the LCD, cannot be fully eliminated in the manufacturing proc e s s
and do not  affect the distancing performance of the unit.
M a g n i f i c a t io n . . . . . . . 6 x
Field of Vi e w . . . . . . . 5 . 7
˚
Eye Relief.......25mm
Exit Pu p i l . . . . . . . 4 . 2 m m
P o w e r   S o u r c e
The  YA RD AGE  PRO
®
750  is  powered  by  one  9-vo l t
alkaline battery.  (Use only  high quality alkaline batteries. Do  not use heavy duty or
lithium batteries).
C L E A N I N G  
Gently blow away any dust or debris on the lenses (or use
a soft lens brush).  To remove dirt or fingerprints, clean with a soft cotton clo t h ,
rubbing in a circular mo t ion.  Use of a coarse cloth or unnec e s s a ry rubbing may
s c r a t ch  the  lens  surface  and  eventually  cause  permanent  damage.    For  a  mo r e
t horough cleaning, pho t ographic lens tissue and pho t og r a p h i c - type lens cleaning
fluid  or  isopropyl  alcohol  may  be  used.    Always  apply  the  fluid  to  the  cleaning
c loth - never directly on the lens.
L A S E R   R A N G I N G   S Y S T E M
I N S T R U C T I O N S
Figure  2
Figure 3
Figure 4
Fire Button
( LCD )
Figure 1
Mode  Button
Continued on page 2
Lit. #:  91-0224/03-01
2 0 - 0 7 5 0
750