Intel S5000XAL BB5000XALR User Manual

Product codes
BB5000XALR
Page of 112
Connector / Header Locations and Pin-outs 
Intel
®
 Server Board S5000PAL / S5000XAL TPS 
 
 
Revision 1.9 
Intel order number: D31979-010 
44 
Connector 
Quantity 
Reference Designators 
Connector Type 
Pin 
Count
System Recovery 
Setting Jumpers 
J1D1, J1D2,  J1D3,  J3H1 
Jumper 
 
5.2 Power 
Connectors 
The main power supply connection is obtained using an SSI compliant 2x12 pin connector (J3K3). In 
addition, there are two additional power related connectors; one SSI compliant 2x4 pin power connector 
(J3K4) providing support for additional 12V, and one SSI compliant 1x5 pin connector (J1K1) providing 
I
2
C monitoring of the power supply. The following tables define the connector pin-outs. 
Table 10. Power Connector Pin-out (J3K3) 
Pin 
Signal 
Color 
Pin 
Signal 
Color 
+3.3Vdc Orange 
13 
+3.3Vdc Orange 
2 +3.3Vdc 
Orange 14 -12Vdc 
Blue 
3 GND 
Black  15 GND 
Black 
4 +5Vdc 
Red  16 PS_ON#  Green 
5 GND 
Black  17 GND 
Black 
6 +5Vdc 
Red  18 GND 
Black 
7 GND 
Black  19 GND 
Black 
8 PWR_OK  Gray  20 RSVD_(-5V) 
White 
9 5VSB 
Purple 21 +5Vdc 
Red 
10 +12Vdc 
Yellow  22 +5Vdc 
Red 
11 +12Vdc 
Yellow  23 +5Vdc 
Red 
12 +3.3Vdc 
Orange 24 GND 
Black 
Table 11. 12V Power Connector Pin-out (J3K4) 
Pin 
Signal 
Color 
1 GND 
Black 
2 GND 
Black 
3 GND 
Black 
4 GND 
Black 
5 +12Vdc 
Yellow/Black
6 +12Vdc 
Yellow/Black
7 +12Vdc 
Yellow/Black
8 +12Vdc 
Yellow/Black
 
Table 12. Power Supply Signal Connector Pin-out (J1K1) 
Pin 
Signal 
Color 
1 SMB_CLK_ESB_FP_PWR_R  Orange 
2 SMB_DAT_ESB_FP_PWR_R  Black 
3 SMB_ALRT_3_ESB_R 
Red 
4 3.3V 
SENSE- 
Yellow 
5 3.3V 
SENSE+ 
Green