Eaton 010-0029 Catalog

Page of 28
U
nde
rst
andi
ng ePDU T
echnolog
ies
eaton.com/epdu 1.800.356.5794
7
Basic (BA) – rugged construction and flexible mounting options (page 10)
Designed for reliable and cost effective power distribution, Basic ePDUs have the form factor and 
receptacle choices to meet the needs of the demanding data center architect. With power levels 
ranging from 1.4 kW all the way to 17 kW, Eaton has the right Basic ePDU for any application.
FlexPDUs and Hot Swap Maintenance Bypass (page 14)
The Eaton FlexPDUs are designed to provide flexible output receptacle options from a single UPS. 
These products have a three-foot input cord, enabling them to be mounted in close proximity to  
the UPS.
Ideal for maintenance and UPS replacement, the Eaton HotSwap Maintenance Bypass facilitates  
hot-swappable UPS replacement without shutting down equipment connected to the UPS.
Monitored Network (MI) (page 16)
Eaton Monitored ePDUs provide remote monitoring of the current draw of individual sections via 
Ethernet or Serial communication. This capability, combined with state-of-the-art software allows 
you to aggregate the information from hundreds of ePDUs in one location. All Monitored ePDUs also 
include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers.
Advanced Monitored (AM) – Current Monitoring Per Outlet (page 19)
Designed for high-density, mission-critical server applications, the Advanced Monitored ePDUs 
provide maximum power for both standard and blade servers by allowing you to monitor at the 
outlet level. Employing multiple configurations, the Easy-Read digital ammeter and remote power 
management with clearly labeled circuits, these ePDUs ensure easy management and monitoring for 
current requirements and future expansion.
Switched (SW) – individual outlet switching and sequencing (page 20)
Designed for data centers needing remote site management, the Switched ePDUs provide remote 
power monitoring of both voltage and current. The current is also displayed on a local two-digit 
current meter. These units also monitor both temperature and humidity. The Switched ePDUs employ 
multiple configurations, available in 0U and 2U rack mount, and 42” or 66” vertical lengths. They 
also provide individual on/off/reboot control of up to 36 receptacles. The control interface is highly 
customizable with multiple functions and flexibility to send either SNMP traps or e-mail alerts.
Eaton Automatic Transfer Switches (AT) (page 22)
Designed for switching non phase synchronized AC power sources, the automatic transfer switch 
ePDUs intelligent circuitry monitors both inputs, providing a fast switch transfer from primary to 
secondary source power critical equipment without interruption. These ePDUs assure the highest 
level of redundancy to mission critical applications.