AC Power
Line Voltage:____________________________________________________120V, 60Hz
Total Current Capacity:__________________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1815 Joules
Peak Impulse Current:___________________________________________73,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:________________________________________90 VAC ± 2 VAC
EMI/RFI Noise Filtration
Total Current Capacity:__________________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1815 Joules
Peak Impulse Current:___________________________________________73,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:________________________________________90 VAC ± 2 VAC
EMI/RFI Noise Filtration
Banks 1 & 2:________________________________________ 80 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:____________________________60 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:____________________________60 db, 100 KHz – 2 MHz
Common Mode (all banks)______________________________60 db, 100 KHz - 2 MHz
DC Trigger Input
Jacks:_______________________________________________3.5mm (1/8”) mini-plug
Voltage and Polarity:___________________________________3 - 24V DC, bidirectional
Current Requirement:_________________________________4.6 mA @3V, 58 mA @24V
Voltage and Polarity:___________________________________3 - 24V DC, bidirectional
Current Requirement:_________________________________4.6 mA @3V, 58 mA @24V
LAN Circuit
Clamping Level:____________________________________________________8V ± 2V
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6
Telephone Circuit (pay-per-view)
Fuseless/Auto-resetting:_________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:_____________________________________________________________RJ-11
Wires Protected:___________________________________________2-Wire, Pins 4 & 5
DSL Compatible:_______________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:_____________________________________________________________RJ-11
Wires Protected:___________________________________________2-Wire, Pins 4 & 5
DSL Compatible:_______________________________________________________Yes
HD Satellite TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:______________________________________< 1db from 950MHz-2.05GHz
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:______________________________________< 1db from 950MHz-2.05GHz
< 2.4db @ 2.2GHz
Connections:__________________________________________Female “F”, Gold Plated
HD Cable TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz - 950MHz
Connections:__________________________________________Female “F”, Gold Plated
Pay-Per-View Compatible________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz - 950MHz
Connections:__________________________________________Female “F”, Gold Plated
Pay-Per-View Compatible________________________________________________Yes
MODEL M5100-EX UNIT CARTON
MASTER CARTON
Dimensions
Weight
Dimensions
Weight UPC Qty Dimensions Weight
UPC
17" x 12.75" x 3.5"
14 lbs
23.75" x 19.25" x 9.5" 17.5 Lbs 0 50616 00785 6 1 Same as 17.5 Lbs 5 00 50616 00785 1
4.1" H with feet
Individual Carton
UPC’s, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
OPTIONAL SILVER BEZEL
SILVER BEZEL
PRODUCT
UNIT CARTON
MASTER CARTON
Model # Dimensions
Weight Dimensions Weight
UPC
Qty Dimensions
Weight
UPC
BEZ5100-EXS 17" W x 0.625" D x 3.5" H 14.5 Oz 18" x 4" x 1" 18.0 Oz 0 50616 00791 7 N/A N/A N/A N/A
1690 Corporate Circle, Petaluma, CA 94954
•
800-472-5555 or 707-283-5900
•
Fax - 707-283-5901
•
www.panamax.com
MAX
®
5100-EX REAR PANEL FEATURES
MAX
®
5100-EX SPECIFICATIONS
Specifications subject to change due to product upgrades and improvements.
Circuit Breaker
Automatically opens
when the current load
is greater than 15
Amps.
when the current load
is greater than 15
Amps.
Ground Lug
Provides a common
grounding point for
equipment with sep-
arate ground leads.
grounding point for
equipment with sep-
arate ground leads.
Main Power
Must be plugged
into a properly
wired & ground-
ed 3-wire outlet
into a properly
wired & ground-
ed 3-wire outlet
Outlet Bank 1
Four always on outlets. Power will only be turned off
under a fault condition. (See specifications for over-
voltage and under-voltage thresholds) Power is cleaned
by a two-stage balanced Pi filter which also provides
noise isolation from Outlet Banks 2 and 3.
under a fault condition. (See specifications for over-
voltage and under-voltage thresholds) Power is cleaned
by a two-stage balanced Pi filter which also provides
noise isolation from Outlet Banks 2 and 3.
Outlet Bank 2
Four switched outlets controlled by the front panel Power
Button or the DC Trigger input. Bank 2 will turn on imme-
diately and turn off after 10 seconds. EMI/RFI noise filtra-
tion is provided by a two-stage balanced Pi filter which
also provides noise isolation from Outlet Banks 1 and 3.
Button or the DC Trigger input. Bank 2 will turn on imme-
diately and turn off after 10 seconds. EMI/RFI noise filtra-
tion is provided by a two-stage balanced Pi filter which
also provides noise isolation from Outlet Banks 1 and 3.
Outlet Bank 3
Two switched, high current outlets controlled by the front panel Power Button or the DC
Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High
Current outlet provides power from a low impedance noise filtration circuit that does not
limit the current to your equipment. Its output is noise isolated from all other outlet banks.
Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High
Current outlet provides power from a low impedance noise filtration circuit that does not
limit the current to your equipment. Its output is noise isolated from all other outlet banks.
Voltage Sense Trigger Input
3.5mm (1/8”) Mini-Plug jack. Connect to
a remote trigger device that uses a DC
output to trigger a startup/shutdown
sequence. This bypasses the front panel
power switch.
a remote trigger device that uses a DC
output to trigger a startup/shutdown
sequence. This bypasses the front panel
power switch.
LAN Jacks
Protection cir-
cuits for 10/100
baseT Ethernet
lines.
cuits for 10/100
baseT Ethernet
lines.
Phone Jacks
Protection circuits for
standard telephone
or pay-per-view lines.
Phone circuit is auto-
resetting.
standard telephone
or pay-per-view lines.
Phone circuit is auto-
resetting.
Satellite TV Coax Jacks
Bidirectional protection circuit opti-
mized for satellite TV signal lines
mized for satellite TV signal lines
.
Cable TV Coax Jacks
Bidirectional protection circuit opti-
mized for cable TV, off-air antennas
and cable modem signal lines.
mized for cable TV, off-air antennas
and cable modem signal lines.
The Power Specialists Since 1975
®
© 2006 Panamax, Inc. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect is a trademark of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc.
Rack Mountable
(rack mount kit not included and sold separately - Rack Mount Kit / Double DIN, Part #
GRM2204)