LG 47LY345C User Guide

Page of 38
32
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
Command Reference List
Communication Parameters
 
y
Baud rate: 9600 bps (UART)
 
y
Data length: 8 bits
 
y
Parity : None
 
y
Stop bit: 1 bit
 
y
Communication code: ASCII code
 
y
Use a crossed (reverse) cable.
* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are not 
executed and treated as NG.
(Depending on model)
(Depending on Model)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power
k
a
00 to 01
13. Balance
k
t
00 to 64
02. Aspect 
Ratio
k
c
(
)
14. Colour 
Temperature
x
u
00 to 64
03. Screen 
Mute
k
d
(
)
15. Energy 
Saving
j
q
00 to 05
04. Volume 
Mute
k
e
00 to 01
16. Auto Con-
figuration
j
u
01
05. Volume 
Control
k
f
00 to 64
17. Equalize
j
v
06. Contrast
k
g
00 to 64
18. Tune Com-
mand
m
a
07. Brightness k
h
00 to 64
19. Programme 
Add/Skip
m
b
00 to 01
08. Colour
k
i
00 to 64
20. Key
m
c
09. Tint
k
j
00 to 64
21. Control 
Back Light
m
g
00 to 64
10. Sharpness k
k
00 to 32
22. Input select 
(Main)
x
b
11. OSD Select k
l
00 to 01
12. Remote 
Control
Lock Mode
k
m
00 to 01