LG 55LV75A-5B User Guide

Page of 84
82
ENG
ENGLISH
CONTROLLING THE MULTIPLE PRODUCT
65. Reading luminance values (Command: m u)
Reads luminance values.
Transmission
[m][u][ ][Set ID][ ][FF][Cr]
Acknowledgement
[u][][SetID][][OK/NG][Data1][Data2][Data3][Data4]
[Data5][Data6][Data7][x]
Data1 00-64 backlight 0-100
Data2 00-ff: Upper 2-byte of CA210 measured value
Data3 00-ff: Lower 2-byte of CA210 measured value
CA210 measured value Hex: 0000-ffff, Decimal: 0 - 
65535
Data4 00-ff: Upper 2-byte of BLU measured value
Data5 00-ff: Lower 2-byte of BLU measured value
Data6 00-ff: Upper 2 bytes of BLU No. 2 sensor 
measured value
Data7 00-ff: Lower 2 bytes of BLU No. 2 sensor 
measured value
BLU measured value Hex: 0000-ffff, Decimal: 0 - 65535
* CA210 measured value is entered through the 
calibration procedure during final assembly. Default 
value is 0 before calibration.
** It may not be supported, depending on the model.
66. Status check (Command: s v)
Check various statuses.
Transmission
[s][v][ ][Set ID][ ][Data][ ][FF][Cr]
Data  05: Check the normal operation of No.1 and 
No.2 luminance sensors.
 
06: luminance sensor being used: 
 
 07: Checks whether the main temperature 
sensors as well as the sensors located at the 
top and bottom work normally.
 
 08: Temperature of each temperature sensor 
when the set is powered off.
 
09: Fan Speed 
 
0x10: RGB sensing OK/NG (Check Screen)
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][x]
When the Data is 05
Data1 00: All normal
 
01: BLU sensor 1 normal, BLU sensor 2 fail
 
02: BLU sensor 1 fail, BLU sensor 2 normal
 
03: All fail
When the Data is 06
Data1 00: No.1 luminance sensor is being used
 
01: No.2 luminance sensor is being used
When the Data is 07
Data1 00: All temperature sensors fail
 
01: Top normal, Bottom fail, Main fail
 
02: Top fail, Bottom normal, Main fail
 
03: Top normal, Bottom normal, Main fail
 
04: Top fail, Bottom fail, Main normal
 
05: Top normal, Bottom fail, Main fail
 
06: Top fail, Bottom normal, Main fail
 
07: All temperature sensors normal
When the Data is 08
Acknowledgement
[v][ ][SetID][ ][OK/NG][Data][Data1][Data2][Data3][x]
Data1: Temperature of the top sensor area when the 
set is powered off.
Data2: Temperature of the bottom sensor area when 
the set is powered off.
Data3: Temperature of the main sensor area when 
the set is powered off.
When the Data is 09
Acknowledgement
[v][ ][SetID][ ][OK/NG][Data][Data1][Data2][x]
Data1  00-ff: Upper 2-byte of Fan Speed
Data2  00-ff: Lower 2-byte of Fan Speed
Fan Speed: Hex 0-20D0, Decimal 0-8400
When the Data is 0x10
Acknowledgement
[v][ ][SetID][ ][OK][Data][Data1][x]
Data1  00: RGB all NG
 
01: B NG. G NG, R OK 
 
02: B NG. G OK, R NG 
 
03: B OK. G OK, R NG 
 
04: B NG. G NG, R OK 
 
05: B OK. G NG, R OK 
 
06: B NG. G OK, R OK 
 
07: RGB all OK
 
08: Loading
** It may not be supported, depending on the model.