LG LDG5315ST User Guide

Page of 120
16 INSTALLATION
Installing the Anti-tip Device
Anti-tip 
bracket
Wall plate
Screw must 
enter wood or 
concrete
The anti-tip bracket is packaged with an installation 
template. The instructions include necessary 
information to complete the installation. Read and 
follow the range installation instruction sheet.
WARNING
 
Range must be secured with an approved  
anti-tip device.
 
The range could be tipped by standing, sitting 
or leaning on an open door if the range or  
anti-tip device is not properly installed.
 
After installing the anti-tip device, verify that it is 
in place by carefully attempting to tilt the range 
forward.
 
This range has been designed to meet all 
recognized industry tip standards for all normal 
conditions.
 
The installation of the anti-tip device must meet 
all local codes for securing the appliance.
 
The use of this device does not preclude tipping 
of the range when not properly installed.
Providing Adequate Gas 
Supply
Your range is designed to operate at a pressure of 
5" of water column on natural gas or 10" of water 
column on LP.
Make sure you are supplying your range with the type 
of gas for which it is configured.
This range is convertible for use on natural or LP gas. 
When using this range on LP gas, conversion must 
be made by a qualified LP installer before attempting 
to operate the range.
For proper operation, the pressure of natural gas 
supplied to the regulator must be between 5" and 13" 
of water column.  
For LP gas, the pressure supplied to the regulator 
must be between 10" and 13" of water column. When 
checking for correct operation of the regulator, the 
inlet pressure must be at least 1" more than the 
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the 
range must remain in the supply line regardless of 
which type of gas is being used.
A flexible metal appliance connector used to connect 
the range to the gas supply line should have an I.D. 
of 
5
/
8
" and a maximum length of 5 feet. In Canada, 
flexible connectors must be single wall metal 
connectors less than 6 feet in length.