Eaton TPC115-10A2/MTD User Manual

Page of 6
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999 
2
RACK MOUNTED
19” x 1.72” (1U) x 8.0”
Approximate shipping weight: 14 lbs.
(10) NEMA OUTLETS
2 unswitched on front and 8 switched    
on rear panel. Unswitched outlets are    
tied to the SW-II outlet section
POWER INPUT
Power cable with plug is attached to unit 
through the rear panel cable grip
(3) INDICATOR LIGHTS
Main breaker power “on” and power to    
the unswitched outlets
Power “on” to the SW-I outlets
Power “on” to the SW-II outlets
SPIKE/SURGE SUPPRESSION
L-N, L-G, N-G
EMI/RFI FILTERING
Common Mode Line to Ground
Differential Mode Line to Line
OVERLOAD CIRCUIT PROTECTION
Electromagnetic breaker 
provides manual on/off switching and    
trips in an overload condition
LOCAL/OFF/REMOTE SWITCHING
Local: Power “on or off” to the switched   
outlets
Off: When breaker is “on” but this switch 
is in the “off” mode, you will have power 
to the unswitched outlets only
Remote: Power “on or off” to the  
 
switched outlets via a remote device
Latching remote, on “LT” systems, has   
the selection switch wired for  
 
Remote/Off/Remote - There is no local   
control
MULTIPLE TIME DELAY™ (MTD™)
Activated “locally” or “remotely”, SW-I   
outlets power up immediately, followed   
four seconds later by SW-II outlets  
 
which is followed four seconds later by   
the sequenced remote I/O port.
Add “/MTD” after part number, i.e. 
TPC115-10-A/MTD
REMOTE I/O PORTS
3 front/2 rear
Remote on/off and EPO control, EPO    
overrides remote and local control
Sequence Power Up additional 
equipment down line (3rd connector on 
front panel)
Latching remote feature - (N/C) EPO,    
momentary start
Add “-LT” to the part number when 
  
the MTD feature is not being used
Add “/LT” to the part number  
 
when the MTD feature is used
SPECIFICATIONS
TPC115-10-A
TPC115-10-A2
TPC115-10-B
TPC115-10-C
TPC115-10-D
TPC115-10-F
Approvals
UL/cUL
UL/cUL
UL/cUL
UL/cUL
UL/cUL
UL/cUL
Voltage Input/Output (50/60Hz)
120V~
120V~
240V~
120V~
120V~
240V~
Current Input
15A
20A
15A
30A
30A
30A
Current Output
12A
16A
12A
24A
24A
24A
Full Load VA
1440VA
1920VA
2880VA
2880VA
2880VA
5760VA
NEMA Outlets
5-15R
5-20R
6-15R
5-15R
5-20R
6-15R
Circuit Breaker with Kick Guard
15A
20A
15/15A
15/15A
15/15A
(2) 15/15A 
EMI/RFI Filter
20A
20A
20A
30A
30A
30A
Multi-Stage Surge Suppression
270V/150V
270V/150V
320V/270V
270V/150V
270V/150V
320V/270V
Power Cord/Length
14/3, 9’
12/3, 9’
14/3, 9’
10/3, 15’
10/3, 15’
10/3, 15’
NEMA Power Input Plug
5-15P
5-20P
N/A
L5-30P
L5-30P
L6-30P
TPC115-10-D Front
TPC115-10-D Rear