Argus 3u Plus 100300 User Manual

Product codes
100300
Page of 3
Tel +49 (0) 2351 9070-0
Fax  +49 (0) 2351 9070-70
www.argus.info/en
 
• BERT bit error test with evaluation in accordance with G.821
- Extended self call end-to-end BERT
- Displays the bit error count and remaining  measuring time 
- G.821 analysis: ES, EFS, SES, US, DM and OK evaluation
- Adjustable service
- Manual injection of bit errors
- Adjustable OK/Not-OK bit error rate threshold and evaluation 
- Test pattern in accordance with O.150: 2E11-1, 2E15-1, user 
defined
- Measurement period: 1 minute up to infinite
- Loopbox function for B-channels and all services
- Audible alarms for bit errors,LOS and  LOS counter 
• Simultaneous use of two connections
• Terminal or net simulation* for different ISDN bearer and tele 
sevices 
• Displays the clear cause by number/text incl. location in plaintext
• Tests of ISDN leased lines: 
- Telephone function and BERT, selectable B-channels, loopbox 
function for B-channels 
- BERT in D-channel
• Time measuremnet: time for connecting, time offset of 
B-channels
• Layer 1 tests and bus supply: Measurement and evaluation of the 
phantom feed (OK, NORMAL or Restricted Power) and the L1 
recieve- and send-signal level of NTBA or PBX  
• Cable testing*: Check-up of the terminating impedance in detail. 
If there are crossed wires or short circuits, the tester displays the 
right wire.
                                                                                                   
                                                                                     
ARGUS
®
3u Series - The U interface function
• U interface in accordance with  ETR 80 / ANSI T1.601 
• Line coding: 4B3T or 2B1Q, RJ 45 with 150 Ohm 
• Automatic U interface detection 
• Test in TE mode at U interface same as at S/T
• Measurement of U interface voltage incl.OK evaluation
• Endurance testing (up to 1200 mW incl. U/I measurement) 
• High-Z monitor with non-intrusive listen-to on U interface (qoud 
vide POTS)
ARGUS
®
3u Series - Basic copper cable testing function*
• Impedance measurement (loop) - accuracy: ~ 10%
- Measurement range: 100 Ohm ... 20k Ohm
- Resolution: <1k: +/- 10 Ohm, >1k: +/- 100 Ohm
• Capacity measuremt (open) - accuracy: ~ 10%
- Measurment range: 1nF ... 1µF
- Resolution: 1nF ... 1µF +/- 1/10 nF
ARGUS
®
3u Series - The POTS interface function*
• Automatic detection of POTS interface
• POTS telephone function with DTMF and pulse dial mode
• Flash function (40-1000 ms)
• Loop resistance: 400 Ohm
• POTS voltage measurement incl. polarity (on-hook and off-hook) 
• CLIP and other caller ID services in acc. ETS 300 659/778
• Supports display FSK and DTMF caller ID 
• Adjustable DTMF signal level, signal and intervall lenght
• High-Z monitor with non instrusive listen-to on POTS)
- Measurement of voltage incl. polarity (up to 300 V)
- Online display of CLIP, date, time,... caller ID services
- Online display of DTMF dailing tones incl. A, B, C, D, *, #
• Works as reciever for tone generators
ARGUS
®
3u  Series - Acoustics* 
• Automatic headset access detection
• Headset connection over jack plug
• Headset operation mode
(Supplementary service test viewed by WINanalyse*)