Example2: Get Brightness from TV-05, but the Brightness command ID is error and it is NOT in the 
command table.
Send (Hex Format) 
Name 
Length
ID
Command 
Type
Command Value1
Value2
Value3
CR
Hex 
0x38
0x30
0x35
0x67
0XD3
0x30
0x30
0x30
0x0D
Reply (Hex Format) 
Name 
Length
ID
Command 
Type
CR
Hex 
0x34
0x30
0x35
0x2D
0x0D
Get function table:
Get Function Length
ID
Command 
Type
Command 
Value Range
Comments
Code (ASCII) 
Code (Hex)
(Three ASCII bytes) 
Get-Contrast 
8
g
a
61
000 ~ 100 
Gets Contrast value
Get-Brightness 
8
g
b
62
000 ~ 100 
Gets Brightness value
Get-Sharpness 
8
g
c
63
000 ~ 100 
Gets Sharpness value
Get-Color 
8
g
d
64
000 ~ 100 
Gets Color value
Get-Tint 
8
g
e
65
000 ~ 100
Gets Tint value
Get-Volume 
8
g
f
66
000 ~ 100 
Gets Volume value
Get-Mute 
8
g
g
67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF 
status
Get-Input select
8
g
j
6A 
000~
See Set-function table
Get-Power 
status : ON/
STBY
8
g
l
6C
000: STBY
001: ON
Get-Remote 
control
8
g
n
6E
000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock
8
g
o
6F
000 : Unlock
001 : Lock
Get-Button Lock
8
g
p
70
000 : Unlock
001 : Lock
Get-Menu Lock
8
g
q
71
000 : Unlock
001 : Lock
Get-ACK
8
g
z
7A
000
This command is 
used to test the 
communication link.
Get-Thermal
8
g
0
30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
For specific models 
only
Get-Power on/
off log
8
g
1
31
000
(See below note)
For specific models 
only
Get-Date
8
g
2
32
000
(See the Set-Date 
command)
For specific models 
only
Get- Time
8
g
3
33
000
(See the Set-Time 
command)
For specific models 
only