Viewsonic CDE4302 User Manual

Page of 51
30
NOTE
1. Behavior at lock modes
Lock Mode
Behavior
Button Lock 
1.  Lock all buttons on the front panel and RCU, except for “Power”
2.  All the SET functions should be workable via RS32, even the ones with 
according hot key in RCU like Mute,…etc.
MENU Lock
1.  Lock “MENU’ key of front panel and RCU
2.  The Factory and Hospitality modes should not be blocked for the model using 
MENU-combined key to enter these two modes. Alternative approach will be 
indicated separately if any limitation by model.
POWER Lock
1.  Lock “POWER” key on the front and RCU. 
2.  The SET_POWER on/off should be workable via RS232, but does not mean 
the POWER lock will be released under this case.
3.  Can not be unlocked by reset in OSD setting
4.  Will auto AC power-on in power-lock
5.  Under power-lock, the set will not enter power saving when no PC signal and 
neither not turn off when no other video signals after 15min.
Remote control disable
Lock the RCU keys, but keep the front panel buttons workable.
2. Example for value setting of SET_TV channel DTV
012-0: 0x 30 31 32
012-1: 0x 30 31 42
1012-2: 0x 41 31 52
1512-3: 0x 46 31 62
3. Tiling definition of H Monitors/ V Monitors/ and Position
H MONITORS
V MONIT
ORS
Position
4. Date & Time format definition
Value 1
Value 2
Value 3
Date
0: Year
Year code of the first 2 digis
Year code of the last 2 digis
1: Month+Day
Month code
Day code
Time
0: Hour(24-hr format)+Min
Hour code
Minute code
1: Sec
0
Second code