Sony VPL-DX145 Manual

Page of 132
17
 GB
Indicators
Indicators
The indicators allow checking the status and notify you of abnormal operation of the projector.
If the projector exhibits abnormal status, address the problem in accordance with the table 
below.
ON/STANDBY indicator
LAMP/COVER indicator
Status
Meaning/Remedies
Lights in red
The projector is in Standby mode.
Flashes in green
• The projector is ready to operate after having been turned on. 
• The lamp cools after the projector is turned off.
Lights in green
The projector’s power is on.
Lights in orange
The projector is in With No Input (Lamp Cutoff).
Flashes in red
The projector is in abnormal status. Symptoms are indicated by 
number of flashes. Address the problem in accordance with the 
following. If a symptom persists, despite having taken measures 
below, consult with qualified Sony personnel.
Flashes twice
The internal temperature is unusually high. Check the items below.
• Check if nothing is blocking the ventilation holes.
• Check if the air filter is not clogged. (page 20)
• Check if the Installation Attitude in the Installation menu is set 
correctly.
Flashes six times
Unplug the AC power cord from a wall outlet. After checking that the 
ON/STANDBY indicator goes out, plug the power cord to a wall 
outlet again then turn on the projector.
Other number of 
flashes
Consult with qualified Sony personnel.
Status
Meaning/Remedies
Flashes in red
Symptoms are indicated by number of flashes. Address the problem in 
accordance with the following.
Flashes twice 
The lamp cover is not attached securely. (page 18)
Flashes three times The temperature of lamp is unusually high. Turn off the power and 
wait for lamp to cool then turn on the power again. If the symptom is 
shown again, the lamp may be burnt out. In this case, replace the lamp 
with a new one (page 18).