Sony VPL-HW40ES Specification Guide

Page of 134
19
 US
The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any trouble with 
your projector.
When a warning indicator other than the above starts flashing, and the symptom persists even after 
carrying out the above methods, consult with qualified Sony personnel. 
Error Handling
Warning Indicators
Symptom
Cause and Remedy
LAMP/COVER flashes in 
red. (A repetition rate of 2 
flashes)
c Close the lamp cover securely, then tighten the screws securely. 
c Close the filter holder securely. 
LAMP/COVER flashes in 
red. (A repetition rate of 3 
flashes)
c The lamp has reached the end of its useful lifespan. Replace the 
lamp. 
c The lamp has reached a high temperature. Wait until the lamp 
cools, and then turn on the power again. 
ON/STANDBY flashes in 
red. (A repetition rate of 4 
flashes)
c The fan is broken. Consult with qualified Sony personnel.
ON/STANDBY flashes in 
red. (A repetition rate of 2 
flashes)
c The internal temperature is unusually high. Check to ensure that 
if nothing is blocking the ventilation holes or whether or not the 
projector is being used at high altitudes.
ON/STANDBY flashes in 
red. (A repetition rate of 6 
flashes)
c Press the I/1 (ON/STANDBY) switch to turn on the projector. 
If the power is not turned on, disconnect the AC power cord, 
then confirm the ON/STANDBY lamp is turned off. After about 
10 seconds, reconnect the AC power cord and turn on the power 
again. If the indicators still light up, the electrical system has a 
problem. Consult with qualified Sony personnel.
Note
ON/STANDBY indicator
LAMP/COVER indicator
If there is any problem or an error message appears on the 
screen, refer to “Troubleshooting” in the Operating 
Instructions contained in the supplied CD-ROM.