Sony A55VHZ Manual

Page of 203
84
• It requires a lot of power to perform high quality movie recording or continuous 
shooting using the APS-C size image sensor. Therefore, if you continue to shoot, the 
temperature inside the camera will rise, especially that of the image sensor. In such 
cases, the camera is turned off automatically since higher temperatures affect the 
quality of the images or burden the internal mechanism of the camera.
• The duration of time available for movie recording is as follows when the camera 
starts recording after the power of the camera has been turned off for a while. (The 
following values indicate the continuous time from when the camera starts recording 
until the camera stops recording.) If you disable the SteadyShot function during 
movie recording, the recording time is longer.
• The duration of time available for movie recording varies with the temperature or 
condition of the camera before you start recording. If you frequently recompose or 
shoot images after the power is turned on, the temperature inside the camera rises 
and the recording time available is shorter than the values indicated in the table 
above.
• If the camera stops recording due to the temperature, leave it for several minutes 
with the power turned off. Start recording after the temperature inside the camera 
drops fully. (When the camera is left for 5 to 10 minutes at a room temperature of 
30°C (86°F), recording will be possible for about 3 to 4 minutes.)
• If you observe the following points, the recording time is longer.
– Keep the camera out of direct sunlight.
– Turn the camera off when it is not being used.
– If possible, use a tripod and disable the SteadyShot function.
• The maximum size of a movie file is about 2 GB. When the file size is about 2 GB, 
the recording stops automatically when the file format is MP4, and a new movie file 
is created automatically when the file format is AVCHD.
• The maximum continuous recording time is 29 minutes.
Notes on continuous movie recording
Ambient temperature
SteadyShot
[On]
[Off]
SLT-A55/
SLT-A55V
20°C (68°F)
About 9 minutes
About 29 minutes
30°C (86°F)
About 6 minutes
About 13 minutes
40°C (104°F)
About 3 minutes
About 5 minutes
SLT-A33
20°C (68°F)
About 11 minutes
About 29 minutes
30°C (86°F)
About 7 minutes
About 22 minutes
40°C (104°F)
About 4 minutes
About 9 minutes