90
US
Calibrating the 
Appropriate Settings 
Automatically
[AUTO CALIBRATION]
D. C. A. C. (Digital Cinema Auto Calibration) 
can set the appropriate surround sound 
automatically.
Note
• The system outputs a loud test sound when [AUTO 
CALIBRATION] starts. You cannot turn the volume 
down. Give consideration to children and neighbors.
• Make sure that the headphones are not connected to 
the unit or surround amplifier. You cannot operate the 
following Steps with the headphones connected.
1
Press FUNCTION +/– repeatedly until 
“DVD” appears in the front panel 
display.
2
Press 
 DISPLAY while the system is 
in stop mode.
The Control Menu display appears on the 
TV screen.
3
Press 
X/x to select 
 [SETUP], 
then press 
.
The options for [SETUP] appear.
4
Press 
X/x to select [CUSTOM], then 
press .
The Setup Display appears.
5
Press 
X/x to select [AUDIO SETUP], 
then press 
.
The options for [AUDIO SETUP] appear.
6
Press 
X/x to select [AUTO 
CALIBRATION], then press 
.
The options for [AUTO CALIBRATION] 
appear.
7
Connect the calibration mic (supplied) 
to the A.CAL MIC jack on the front 
panel
Set up the calibration mic at the ear level 
using a tripod, etc. (not supplied).
The front of each speaker should face the 
calibration mic, and there should be no 
obstruction between the speakers and the 
calibration mic.
8
Press 
C/c to select [YES].
9
Press .
[AUTO CALIBRATION] starts.
Be quiet during the measurement.
Note
• Before [AUTO CALIBRATION], make sure 
that the surround amplifier turns on and you 
install the surround amplifier in the appropriate 
location. If you install the surround amplifier in 
an improper location, such as another room, 
proper measurement will not be obtained.
• Avoid being in the measurement area and 
making noise during the measurement (about 3 
minute), to avoid measurement failure. During 
the measurement, test signals are output from 
the speakers.
• The environment of the room in which the 
system is installed may affect measurements.
AUDIO IN / A.C
AL MIC
Calibration mic
E.g., DAV-HDX576WF