Eaton T2235-A2-CFB09S User Manual

Page of 5
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999 
2
Option 5
09S 
= 9’ cable with straight blade plug
09L = 9’ cable with locking plug
15S = 15’ cable with straight blade plug
15L = 15’ cable with locking plug
C20 = IEC C20 power inlet, cables ordered 
separately, AB version only
Option 1
A1 
= 120V/15A input, 12A output
        Receptacles: (8) NEMA 5-15R 
A2 = 120V/20A input, 16A output
        Receptacles: (8) NEMA 5-20R
AB = 100-240V/20A input, 16A output
        Output: (8) IEC C13 (1) IEC C19 
C1 = 120V/30A input, 24A output
        Receptacles: (8) NEMA 5-15R   
C2 = 120V/30A input, 24A output
        Receptacles: (8) NEMA 5-20R  
F3 = 200-240V/30A input, 24A output
       Output: (12) IEC C13    
F4 = 200-240V/30A input, 24A output
       Output: (4) IEC C13 (2) IEC C19   
Option 3
F
 = Filtering
N = No Filtering
Option 2
C
 = Circuit Breaker
N = No Circuit Breaker
T 2 2 3 5 -
-
T2235 “Design Your Own” part number guide
PHYSICAL
Height 1.72” (1U) x Depth 7.0”
Depth 9.5” - Versions C2, F3, F4
Powder coated black steel 
Detachable mounting brackets allow for 
several mounting options
DUAL POWER INPUT
Power cables with plugs are attached to 
unit through the rear panel cable grip
-AB version has C20 inlets 
• Cables must be ordered separately 
OVERLOAD CIRCUIT PROTECTION
(Optional) Electromagnetic circuit  
 
breakers with long time delay curve 
Circuit breaker trip guards are provided
C1, C2, F3, F4 require circuit breakers    
for branch circuit protection to meet  
 
NEC and UL requirements
INDICATOR LIGHTS
(5) LED Indicator lights:
Main Power, Primary Available,  
 
Secondary Available, Primary Output,    
Secondary Output
POWER OUTLETS
North American versions have NEMA    
style receptacles, (8) on the rear
International versions have IEC style    
receptacles, (6-12) on the rear
Optional cable restraint system with  
 
cable management.
POWER FILTERING (Optional)
High performance EMI/RFI filtering  
 
provides protection from both 
electromagnetic and radio 
frequency interference
Filtering is both Common Mode 
(Line to Ground) and Differential 
Mode (Line to Line)
SPIKE/SURGE SUPPRESSION (TVSS)
Transient voltage surge suppression  
 
prevents damage due to voltage  
 
fluctuations
Metal Oxide Varistors (MOVs) are  
 
utilized Line to Line (or neutral)
AUTO TRANSFER SWITCH
Firm drop out points allow a transfer before
an under-voltage will affect equipment    
operation
Transfer ranges (Voltage): 
Sources do NOT need to be phase  
 
synchronized
Source transfer time of less than 30ms   
(clean sine wave to clean sine wave)
Front panel LED’s indicate which sources 
are available and selected at the output
VOLTAGE RANGE SELECTION
The “AB” International (IEC) version  
 
allows for all three voltage ranges 120V, 
208V, or 240V
Front panel switch to set the drop out    
and pull in range to the desired  
 
voltages see chart above
This allows this one version to be  
 
specified for worldwide usage
T2235-AB Front
A2 - Version Back
AB - Version Back
Switches out of Phase Power sources. Optional power Filtering and Circuit Breaker
Nominal
Drop Out
Pull In
120V
90V
103V
208V
182V
195V
240V
197V
210V
AB - Version
ONLY
B
Option 4
B
 = Color Black - Adjustable Mounting