Sony ECM-TL3 Manual

Page of 2
Electret Condenser 
Microphone
ECM-TL3
©2011   Sony Corporation
Printed in China
English
Electret Condenser 
Microphone
WARNING
To reduce the risk of fire or electric 
shock, do not expose this 
apparatus to rain or moisture.
To reduce the risk of electrical 
shock, do not open the cabinet. 
Refer servicing to qualified 
personnel only.
You are cautioned that any changes or 
modifications not expressly approved 
in this manual could void your 
authority to operate this equipment.
Features
  Records both sides of the telephone 
conversation clearly.
  Best to use with a mobile phone 
and/or landline.
  The microphone is covered with 
silicon rubber to reduce noise when 
it hits the receiver.
How to use  
(see fig. )
Connect the plug to the 
microphone jack of a plug-in-
power system recording device.
Wear the earpiece () securely 
in your ear.
Put the speaker of the 
telephone or mobile (
) next 
to the microphone (
).
Align the holes in the speaker with 
the holes of the microphone.
How to change the 
earbud (see fig. )
If you cannot hear low sounds, or the 
earbud does not fit your ear, try 
another size. Confirm the size of the 
earbud by checking the colored part 
( of the sectional view) inside.
When you change the earbud, install it 
firmly on the microphone to prevent 
the earbud from detaching and 
remaining in your ear.
Earbud sizes (inside color)
Small 
Large 
SS
(Red)
(Orange)
(Green)
(Light blue)
* This size is optional and available at 
purchase.
To detach an earbud 
(see fig. )
Twist and pull the earbud off.
 Tip
If the earbud slips and cannot be detached, 
wrap it in a dry soft cloth.
To attach an earbud 
(see fig. )
Push the parts inside of the earbud into 
the microphone until the projecting 
part of the microphone is fully covered.
Troubleshooting
No sound, unable to record
  The connected recorder is not a 
plug-in-power supply system device.
 Connect the microphone to a 
plug-in-power supply system 
device.
 Check with the operating 
instructions of the connected 
device.
  The connected recorder is a 
monaural device.
 Use a PC-236MS stereo-monaural 
converter plug (sold separately).
  The microphone is connected to the 
headphone jack.
 Connect the microphone to the 
microphone jack.
No sound, noisy sound
  The plug does not fit properly.
 Wipe the plug with a soft cloth.
 Insert the plug all the way into the 
microphone jack, and make sure it 
is secure.
Specifications
Type: 
Electret condenser 
microphone
Plug: 
Three-conductor L-shaped 
gold-plated mini plug 
(monaural)
Power supply: 
 
Plug-in-power supply 
system
Wearing system: 
 
Inner ear system
Directivity: 
 
Omni-directional
Front sensitivity (Open circuit 
output voltage level):
 
–35.0 dB (1,000 Hz, 0 dB = 
1 V/Pa)
Frequency response:   
20 Hz - 20,000 Hz
Cord length: 
 
Approx. 1.5 m (59 1/8 in)
Mass: 
Approx. 8 g (0.28 oz) (Incl. 
cord)
Operating temperature: 
 
5 °C to 35 °C  
(41 °F to 95 °F)
Supplied accessories:  
Earbuds  
(S × 1, M × 1, L × 1)
Optional accessory:   
PC-236MS stereo-monaural 
converter plug
 
If the microphone is 
connected to a monaural 
recorder, the microphone 
may not be able to work to 
its full capability, depending 
on the recorder. In such a 
case, use the PC-236MS 
stereo-monaural converter 
plug.
Recommended accessory: 
EP-EX10A earbud
Design and specifications are subject 
to change without notice.
Precautions
  This microphone is a precision 
instrument. Never disassemble it.
  Do not expose the microphone to a 
mechanical shock such as by 
dropping or striking it.
  If the microphone is placed near 
speakers/headphones, a high pitched 
noise may be heard (howling effect). 
This is caused by the microphone 
catching sound from the speakers/
headphones repeatedly. In this case, 
place the microphone as far as 
possible from the speakers/
headphones.
  Do not leave the microphone in a 
humid, dusty or hot place, or under 
direct sunlight. This may cause a 
malfunction.
  When using outdoors, never let the 
microphone become wet with rain 
or saltwater.
  When the microphone and the plug 
become dirty, wipe them with a dry 
cloth. Do not blow on the 
microphone when dusting it. A dirty 
plug will cause deterioration of 
sound quality and intermitted 
sound.
  Always hold the plug when 
disconnecting. Pulling the cord may 
cause it to snap.
  Clean the earbud by hand-washing 
with a mild detergent solution. 
Remove the earbud when you clean 
it. After cleaning, dry the earpiece 
well before use.
  The earbud may deteriorate due to 
long-term storage or use.
Note on static electricity 
In particularly dry air conditions, mild 
tingling may be felt on your ears. This 
is a result of static electricity 
accumulated in the body, and not a 
malfunction of the microphone.  
The effect can be minimized by 
wearing clothes made from natural 
materials.
EP-EX10A is available (sold 
separately) as optional replacement 
earbuds.
EP-EX10A offers 4 types of the 
earbuds: SS, S, M and L.
4-273-321-11(1)
  
MIC  
(PLUG IN POWER)
1
2
3
Operating Instructions
Mode d’emploi
Manual de instrucciones