D-Link DMI-128ESU User Manual

Page of 61
D-LINK ISDN TA DMI-128ESU+ 
54 
APPENDIX  
 
APPENDIX 1 DCE 9Pin D Type Connector Definition 
 
1
2
3
5
4
6
7
8
9
 
 
Pin Signal 
Name  Direction 
Description 
3 SD, 
Send 
Data 
Æ 
DTE send data to TA 
RD, Receive Data 
Å 
TA send data to DTE 
RS, Request to Send 
Æ 
DTE request to send data 
CS, Clear to Send 
Å 
TA inform DTE can to send data 
DR, Data Set Ready 
Å 
TA is ready receiving command from DTE 
SG, Signal Ground 
Å 
TA signal ground (GND) 
CD, Carrier Detect 
Å 
TA inform DTE that has a call incoming already 
ER, Data Terminal Ready 
Æ 
DTE is ready, it can working now 
9 CI, 
Ring 
Indication 
Å 
Incoming ring indication 
 
 
 
Terminating Resistor Settings (DIP Switch inside Battery Compartment)  
 
              
               
 
Switch SW2 
DIP Switch 1,2  - ON (default) =100 ohm Terminating    
                                                       Resistor 
DIP Switch 1,2  - OFF              =0 ohm Terminating 
                                                       Resistor 
DIP Switch 3    - OFF (default) =N.A Keep in OFF Mode 
DIP Switch 4    - OFF (default) =N.A Keep in OFF Mode 
 
The Terminating Resistor of 100 ohm should be set in the 
DMI-128ESU+, when your NT1 is set to 100 ohms, in the 
point-to-point connection, between NT1 and TA.