D-Link DAS-3248DC_revC Leaflet
Alarm I/O:
Connections:
Alarm input could connect to such "fire alarm", "door open alarm" ...etc.
Alarm output could connect to "Speaker", "alarm LED" ...etc.
Alarm input could connect to such "fire alarm", "door open alarm" ...etc.
Alarm output could connect to "Speaker", "alarm LED" ...etc.
Description for each contact:
NA, NA, CO1, NO1, NC1
Reply: NA = no used, it is empty pin/socket.
When the DSLAM alarm = 0, CO1 and NC1 is short.
When the DSLAM alarm = 1, CO1 and NO1 is short.
NA, NA, CO1, NO1, NC1
Reply: NA = no used, it is empty pin/socket.
When the DSLAM alarm = 0, CO1 and NC1 is short.
When the DSLAM alarm = 1, CO1 and NO1 is short.
Circuits:
By default configuration, 4 x alarm input are opened, and CO1 and NC1 are short with alarm
output.
By default configuration, 4 x alarm input are opened, and CO1 and NC1 are short with alarm
output.
Voltages:
The maximum current and voltage for alarm module of DAS3series_RevC is restricted to 2A
24VDC or 1A 120VAC (resistive load).
The maximum current and voltage for alarm module of DAS3series_RevC is restricted to 2A
24VDC or 1A 120VAC (resistive load).