KitchenAid KDRS483VSS Installation Guide

Page of 52
22
GAS CONVERSIONS
IMPORTANT: Gas conversions from Natural gas to LP gas 
must be done by a qualified installer.
LP Gas Conversion
1.  Turn the manual shut-off valve to the closed position.
2.  Unplug range, or disconnect power.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 
instructions.
Slide range back so rear range foot is engaged in the 
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 
and engaged.
Failure to follow these instructions can result in death 
or serious burns to children and adults.
A
A.  To range
B.  Shut-off valve (closed position)
C.  Gas supply line