3
Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood 
combination above the cooktop, follow range hood or microwave 
hood combination instructions for dimensional clearances above 
the cooktop surface.
NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.
If cabinet has a drawer, a 3" (7.6 cm) depth clearance from the 
countertop to the top of the drawer (or other obstruction) in base 
cabinet is required.
For model 15" (38.1 cm) model only:
Electrical Requirements
For 15" (38.1 cm) model only:
For all models except 15" (38.1 cm) model: 
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.
A. 15" (38.1 cm) on 15" (38.1 cm) models; 30" (76.2 cm) on 
30" (76.2 cm) models; 36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box 
above)
C. 30" (76.2 cm) minimum clearance between top of cooktop 
platform and bottom of uncovered wood or metal cabinet (24" 
[61 cm] minimum clearance if bottom of wood or metal cabinet 
is covered by not less than 
¹⁄₄" [0.6 cm] flame retardant 
millboard covered with not less than No. 28 MSG sheet steel, 
0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum 
or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 2" (5.1 cm)
F. 20½" (52 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to 
countertop within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 
countertop
I. Junction box or outlet; 10" (25.4 cm) from right side of cabinet
J. 14½" (36.8 cm) on 15" (38.1 cm) models; 29½" (74.9 cm) on 
30" (76.2 cm) models; 35½" (90.2 cm) on 36" (91.4 cm) models
K. 1" (2.5 cm) minimum distance to nearest left and right side 
combustible surface above cooktop
L. 1½" (3.8 cm) max. counter thickness on 15" (38.1 cm) models. 
See the following illustration.
M. 1" (2.5 cm) minimum clearance between back wall and 
countertop
B
D
A
C
E
F
J
K
G
L
M
I
H
A.
¹¹⁄₁₆" (1.7 cm) min.
B. 1½" (3.8 cm) max.
back edge
of cutout
rear of cabinet or
rear wall under
countertop
 
B
A
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death, 
fire, or electrical shock.