ASUS ESC4000 User Manual

Page of 162
ASUS ESC4000 Series
6-17
3.  After selecting the drive to rebuild, press <F10>. When prompted, press <Y> 
to rebuild the drive.
4.  When rebuild is complete, press any key to continue.
Management Menu
Configure
 
Initialize 
Objects 
Rebuild
 
Check Consistency
Port # 1 DISK   77247MB   HDS728080PLA380   PF20A60A
REBUILD - PHYSICAL DRIVES SELECTION MENU
PORT #
ONLIN A00-00
RBLD  A00-01
0
1
Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version   A.08.09161344R
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
6.2.5 
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual 
drive. The utility can automatically detect and/or detect and correct any differences in 
data redundancy depending on the selected option in the Objects > Adapter menu.
The Check Consistency command is available only for virtual drives included 
in a RAID 1 or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the Check Consistency command
1.  From the Management Menu, select Check Consistency, and then press 
<Enter>.
Management Menu
Configure
 
Initialize 
Objects 
Rebuild 
Check Consistency
CC Of VD(s)
LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008
BIOS Version   A.08.09161344R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option