ASUS ESC4000 User Manual

Page of 162
6-30
Chapter 6: RAID configuration
Select a destination disk with the same size as the original hard disk.
[
 
DEGRADED VOLUME DETECTED
 
]
[↑↓]-Previous/Next  [ENTER]-Select  [ESC]-Exit
"Degraded" volume and disk available for rebuilding detected. Selecting 
a disk initiates a rebuild. Rebuild completes in the operating system.
 
Select the port of destination disk for rebuilding (ESC to exit): 
 
Port Drive Model      Serial #         Size 
 
X    XXXXXXXXXXX      XXXXXXXX         XX.XGB
6.3.7 
Rebuilding the RAID
This option is only for the RAID 1, RAID 5 and RAID 10 sets.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID 1 array failed, the system 
displays the status of the RAID volume as “Degraded” during POST. You can 
rebuild the RAID array with other installed non-RAID disks. 
To rebuild the RAID with other non-RAID disk:
1.  At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage Manager 
option ROM utility. 
2.  If there is a non-RAID SATA Hard Disk available, the utility will prompt to 
rebuild the RAID. Press <Enter>, and then use up/down arrow keys to select  
the destination disk or press <ESC> to exit.
6.3.6 
Exiting the Intel
®
 Matrix Storage Manager
To exit the utility
1.  From the utility main menu, select 5. Exit, and then press <Enter>. The 
following warning message appears.
2.  Press <Y> to exit or press <N> to return to the utility main menu.
Are you sure you want to exit? (Y/N):
[
 
CONFIRM EXIT
 
]