Zone B: Machine status icons:
1. CP Bourg logo.
Pressing this button displays information relating to the version of the UI software
installed.
2. Display of the number of bindings carried out and the total number in the current job.
Pressing this button toggles between the "series" mode, “semi-series” mode and the
"unit" mode.
For more details on this subject, see chapter
3. Start/stop heating the glue tank
+
display of the current glue temperature and the required gluing temperature (*).
Pressing on the left half of the button activates or deactivates the heating and
rotation of the glue cylinders.
The button also displays the current tank temperature (in this example: 144°C) as
well as the required gluing temperature (in this example: 145°C).
4. Machine ready to operate (green traffic light) or not (red traffic light).
5. Keyboard locked/unlocked.
5. Keyboard locked/unlocked.
When the binder is in operation, the keyboard is locked (the padlock is closed) to
avoid parameter values being changed during the binding of a book.
When the carriage is above the loading console, the keyboard is unlocked (the
When the carriage is above the loading console, the keyboard is unlocked (the
padlock is open). The operator can change the binding parameters of the current job.
6. "Reload cover" button.
Pressing this button raises the suction bar.
The operator can then reload the cover station.
The suction bar will automatically move down to the height of the pile next time a
cover is picked up.
This button is also used to open the cover transport jaws in the event of a paper jam
during clamping.
Note: (*): - If the
icon is pressed, the glue temperature will decrease from the
required gluing temperature (
144
°C in this example) to the tank temperature.
The cylinders also stop rotating. However, the operator can vary this
temperature by ±
temperature by ±
15
°C using the graphical interface - see chapter
6
1
2
3
4
5