Netgear M4300-12X12F (XSM4324S) - Stackable Managed Switch with 24x10G including 12x10GBASE-T and 12xSFP+ Layer 3 User Manual
Configure System Information
113
M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual
The Unit Selection field displays the current PoE unit.
6.
To change the PoE unit, select another unit from the list.
7.
To set the System Usage Threshold percentage, enter a number from 1 to 99.
This sets the threshold level at which a trap is sent if consumed power is greater than the
threshold power.
threshold power.
8.
The Power Management mode is the method by which the PoE controller determines
supplied power, which can be one of the following:
•
Select Static to indicate that the power allocated for each is reserved and is not
available to any other port, even when less than the maximum allocation is being
used.
available to any other port, even when less than the maximum allocation is being
used.
•
Select Dynamic to indicate that the power consumption on each port is measured
and calculated in real-time. The power allocated to each port is not reserved. Unused
power may be allocated from one port to another as needed, up to the power limit
defined for each port.
and calculated in real-time. The power allocated to each port is not reserved. Unused
power may be allocated from one port to another as needed, up to the power limit
defined for each port.
9.
To set the traps, select Enable to activate the PoE traps.
Select Disable to deactivate the PoE traps. The default setting is enabled.
10.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
immediately.
The following table describes the PoE Configuration nonconfigurable fields.
Table 43. PoE Configuration
Field
Description
Units
The current PoE Unit. You can change the PoE Unit by selecting
another unit ID listed here.
another unit ID listed here.
Firmware Version
The version of the PoE controller's FW image.
Power Status
Indicates the power status.
Total Power (Main AC)
The total power provided by the MAIN AC power source.
Total Power (RPS)
Total Power (PD) for GSM5212P
switches only
Total Power (PD) for GSM5212P
switches only
The total power provided by the redundant power source.
Power Source
Current source of system power (Main AC or RPS).