Netgear GS728TPP – 28PT GE POE+ SMART SWITCH Administrator's Guide
Configuration Examples
262
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
3.
Configure the following settings for Class1:
•
Protocol Type. UDP
•
Source IP Address. 192.12.1.0
•
Source Mask. 255.255.255.0
•
Source L4 Port. Other, and enter 4567 as the source port value
•
Destination IP Address. 192.12.2.0
•
Destination Mask. 255.255.255.0
•
Destination L4 Port. Other, and enter 4568 as the destination port value
147.
4.
Click APPLY.
5.
In the Policy Configuration screen, create a policy with the following settings:
•
Policy Selector. Policy1
•
Member Class. Class1
153.
6.
Click ADD to add the new policy.
7.
Click the Policy1 to view the Policy Class Configuration screen for this policy.
8.
Configure the policy attributes as follows:
•
Assign Queue. 3
•
Policy Attribute. Simple Policy
•
Color Mode. Color Blind
•
Committed Rate. 10,000 Kbps
•
Committed Burst Size. 128 KB
•
Confirm Action. Send
•
Violate Action. Drop
153.
9.
In the Service Configuration screen, select the check box next to interfaces g7 and g8 to
attach the policy to these interfaces, and click APPLY.
All UDP packet flows destined to the 192.12.2.0 network with an IP source address from the
192.12.1.0 network that have a Layer 4 source port of 4567 and destination port of 4568 from
this switch on ports 7 and 8 are assigned to hardware queue 3.
this switch on ports 7 and 8 are assigned to hardware queue 3.
On this network, traffic from streaming applications uses UDP port 4567 as the source and
4568 as the destination. This real-time traffic is time sensitive, so it is assigned to a
high-priority hardware queue. By default, data traffic uses hardware queue 0, which is
designated as a best effort queue.
4568 as the destination. This real-time traffic is time sensitive, so it is assigned to a
high-priority hardware queue. By default, data traffic uses hardware queue 0, which is
designated as a best effort queue.