Netgear M4300-52G-PoE+ (GSM4352PA) - 48x1G PoE+ Stackable Managed Switch with 2x10GBASE-T and 2xSFP+ (550W PSU) User Manual

Page of 700
Configure System Information 
27
 M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
4. 
Click the Login button. 
The System Information page displays.
5. 
Select System > Management > Initial Setup.
The Initial Setup page displays.
6. 
Scroll down to display the IPv4 Management VLAN Configuration section of the page.
7. 
Specify the Management VLAN ID of the switch. 
The management VLAN is used for management of the switch. The VLAN ID can be any 
value from 1 to 4093.
8. 
Select the radio button to Enable or Disable the global Routing Mode on the device. 
The default is Enable.
9. 
Select the IPv4 Address Assignment DHCP or Static radio button.
This specifies the method for getting IPv4 network parameters (IPv4 address and 
network mask) for the configured management VLAN interface. The default value for 
VLAN 1 is Static.
10. 
In the IP Address field, specify the IP address of the management VLAN interface. 
The factory default value is 169.254.100.100.
11. 
In the Subnet Mask field, specify the IP subnet mask for the management VLAN interface.
This is also referred to as the subnet/network mask and defines the portion of the 
interface’s IP address that is used to identify the attached network. The factory default 
value is 255.255.0.0.
12. 
In the Gateway field, specify the default gateway for the management VLAN interface. 
The default value is 0.0.0.0.
13. 
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect 
immediately.