Netgear M4300-8X8F (XSM4316S) - Stackable Managed Switch with 16x10G including 8x10GBASE-T and 8xSFP+ Layer 3 User Manual
Monitor the System
649
M4200 and M4300 Series ProSAFE Managed Switches Web Management User Manual
Sampling is not stopped until the No Timeout selected entry is True. The default value is
False.
False.
10.
In the Maximum Datagram Size field, specify the maximum number of data bytes that can
be sent in a single sample datagram.
Set this value to avoid fragmentation of the sFlow datagrams. The default value is 1400.
The allowed range is 200 to 12188.
The allowed range is 200 to 12188.
11.
In the Receiver Address field, specify the IP address of the sFlow collector.
If set to 0.0.0.0, no sFlow datagrams are sent.
12.
In the Receiver Port field, specify the destination port for sFlow datagrams.
The allowed range is 1 to 65535.
13.
The Receiver Datagram Version field displays the version of sFlow datagrams to be sent.
14.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
immediately.
Configure the sFlow Interface
sFlow agent collects statistical packet-based sampling of switched flows and sends them to
the configured receivers. A data source configured to collect flow samples is called a
sampler. sFlow agent also collects time-based sampling of network interface statistics and
sends them to the configured sFlow receivers. A data source configured to collect counter
samples is called a poller.
the configured receivers. A data source configured to collect flow samples is called a
sampler. sFlow agent also collects time-based sampling of network interface statistics and
sends them to the configured sFlow receivers. A data source configured to collect counter
samples is called a poller.
To configure the sFlow Interface:
1.
Launch a web browser.
2.
Enter http://<ipaddress> in the web browser address field.
The login window opens.
3.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
4.
Click the Login button.
The System Information page displays.
5.
Select Monitoring
> sFlow > Advanced > sFlow Interface Configuration.