Netgear FVS318v3 – Cable/DSL ProSafe VPN Firewall with 8-Port Switch Reference Manual

Page of 184
ProSafe VPN Firewall FVS318v3 Reference Manual
Troubleshooting
8-7
v5.0, January 2012
Use the Reset button on the rear panel of the firewall. Use this method for cases when the 
administration password or IP address are not known.
1. Press and hold the Reset button until the Test LED turns on and begins blinking (about 10 
seconds).
2. Release the Reset button and wait for the firewall to reboot.
Problems with Date and Time
The E-Mail menu in the Content Filtering section displays the current date and time of day. The 
VPN firewall uses the Network Time Protocol (NTP) to obtain the current time from one of 
several Network Time Servers on the Internet. Each entry in the log is stamped with the date and 
time of day. Problems with the date and time function can include:
Date shown is January 1, 2000. Cause: The firewall has not yet successfully reached a 
Network Time Server. Check that your Internet access settings are configured correctly. If you 
have just completed configuring the firewall, wait at least five minutes and check the date and 
time again.
Time is off by one hour. Cause: The firewall does not automatically sense Daylight Savings 
Time. In the E-Mail menu, check or uncheck the box marked Adjust for Daylight Savings 
Time
.