Netgear RD521210 – ReadyDATA 5200 12TB SATA Bundle includes RD5200 with 2 x RD5D6LT01 Disk Packs Brochure

Page of 34
Page 6
 
Switch Side Configuration
Before we get into LAG configuration, be sure to create a dedicated storage VLAN. In the management interface  
of the switch, go to 
Switching -> VLAN and create the VLAN (In our example it is VLAN 51 and we name it  
NFS Storage).
After creating the storage VLAN, go to 
Switching -> LAG. You will see the different port channels available on  
the switch. Select a channel that is unused (in this example it is ch5) and check the box next to it. At the top  
row, enter in the details such as 
LAG Name and Admin mode. Make sure the Enable option is selected in Admin 
Mode. This determines whether the LAG is enabled or not. For this particular port channel we will also set Static 
Mode as Disable as we will be using LACP rather than just a static LAG. 
Now click 
Apply.
The LAG 
RD-VMware is now created.