Managing System Settings
3-25
v1.0, September 2007
To configure SNMPv1/v2 trap station management:
1. Click System > SNMP > SNMPv1/v2 > Trap Configuration. The SNMPv1/v2 Trap
Configuration screen displays:
The SNMPv1/v2 Trap Configuration screen contains the following fields:
•
Recipients IP – Enter the IP address to which the traps are sent.
•
Notification Type – (Configurable only if the Notification Version is SNMPv2.) Select
the type of notification sent. The possible field values are:
the type of notification sent. The possible field values are:
–
Traps – Traps are sent.
–
Informs – Informs are sent only when SNMPv2 is enabled.
•
Community String – Enter the community string of the trap manager.
•
Notification Version – Select the trap type. The possible field values are:
–
SNMPv1 – SNMP Version 1 traps are sent.
–
SNMPv2 – SNMP Version 2c traps are sent.
•
UDP Port – Enter the UDP port used to send notifications. The default UDP port is 162.
•
Timeout – Enter the amount of time (in seconds) the device waits before re-sending
informs. The default is 15 seconds.
informs. The default is 15 seconds.
•
Retries – Enter the amount of times the device re-sends an inform request. The default is 3
seconds.
seconds.
2. Select the trap entry.
3. Enter the fields in the first row.
4. Click APPLY to update the device.
Figure 3-13