8. Enter the Timeout and Retries in the provided fields in the first row.
9. Click ADD to update the device.
To remove a trap:
1. Click System > SNMP > SNMPv3 > Trap Configuration. The SNMPv3 Trap Configuration 
screen displays.
2. Select the trap entry.
3. Click DELETE to remove the entry.
Trap Filter Name
The SNMPv3 Trap Filter Name screen permits filtering traps based on OIDs. Each OID is linked 
to a device feature or a portion of a feature. The SNMPv3 Trap Filter Name screen also allows 
network managers to filter notifications.
To define the SNMPv3 Trap Filter Name:
1. Click System > SNMP > SNMPv3 > Trap Filter Name. The SNMPv3 Trap Filter Name 
screen displays:
The SNMPv3 Trap Filter Name screen contains the following field: 
Filter Name – Enter the user-defined notification filter name.
2. Select the trap filter entry.
3. Enter the trap Filter Name in the provided field in the first row.
4. Click APPLY to update the device.
Figure 3-22