Netgear RN422X122 – ReadyNAS 4220 2U 12-Bay 12x2TB Enterprise Drives w/ 2x 10GbE Hardware Manual

Page of 96
Status Indicator
Boot Mode
Power
LED
LAN 2
LED
LAN 1
LED
Error
LED
Description
Error LED and both LAN LEDs blink. Power
LED lights.
Boot menu
LAN 2 and Power LEDs light.
Normal
LAN 1 and Power LEDs light.
Factory default
Both LAN LEDs and the Power LED light.
OS reinstall
Error and Power LEDs light.
Tech support
Error, LAN 2, and Power LEDs light.
Volume read only
Error, LAN 1, and Power LEDs light.
Memory test
All four LEDs light.
Test disk
Legend:
Solid:
Blinking:
Off:
6.
Press and hold the Reset button for five seconds to confirm your boot menu selection.
The system boots in the selected boot mode.
Rack Mounting
You can rack-mount the ReadyNAS 2120 and 2120 v2 storage systems using the included rack-mount ears.
Alternatively, you can use the optional sliding rail kit, order number RRAIL04-10000S. For instructions, see
the 1U Rail Installation Guide, which is available at 
ReadyNAS 2120 and 2120 v2
16
ReadyNAS OS 6.5