7.  Tip the terminal box cover at the screw flange area to  
 
  remove. Remove the terminal box cover and set it aside.
A. Terminal box cover
8.  Remove the power supply knockout from the top or rear of
   the vent hood (depending on the incoming location of your
   home power supply cable) and install a UL Listed or CSA
   approved ½” strain relief.
A. Power supply knockout
9.  Using 2 or more people, lift the hood into final position.  
    Feed enough electrical wire through the ½" UL listed or CSA 
    approved strain relief to make connections in the terminal
    box. Tighten the strain relief screws.
10. Position the range hood so that the large end of the keyhole
    slots are over the mounting screws. Then push the hood
    toward the wall so that the screws are in the neck of the    
   slots. Tighten the mounting screws, making sure the screws  
   are in the narrow neck of slots.
11. Connect ventwork to hood. Seal joints with clamps to make
    secure and airtight.
12. Check that back draft dampers work properly.
Make Electrical Connection
1.  Disconnect power.
A. White wires
B. Black wires
C. UL listed wire connector
D. Green (or bare) and yellow-green ground wire
E.  Home power supply cable
F.  UL listed or CSA approved ½" strain relief
2.  Use UL listed wire connectors and connect white wires (A)
  
together.
3.  Use UL listed wire connectors and connect black wires (B)
  
together.
4.  Connect green (or bare) ground wire from home power  
 
  supply to yellow-green ground wire (C) in terminal box using  
  UL listed wire connectors.
5.  Reinstall terminal box cover.
6.  Check that the light bulb is secure in its socket. See
   "Replacing the Fluorescent Lamp" in the Range Hood Care
  
section.
7.  Reconnect power.
Complete Installation
1.  Replace grease filters. See the “Range Hood Care” section.
2.  Check the operation of the range hood fan and light. See
   “Range Hood Use” section.
   If range hood does not operate, check to see whether a
   circuit breaker has tripped or a household fuse has blown.
   Disconnect power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the “Range Hood Use” section.
A
A
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.