Install Range Hood
Install Vent System
1.  Install vent through the vent opening in upper cabinet or    
  wall. Complete venting system according to the selected    
  venting method. See “Venting Requirements” section.
2.  Use caulking to seal exterior wall or roof opening around the  
 cap.
Complete Preparation
1.  Remove the grease filters. See the “Range Hood Care”  
 
 section.
2.  Lift the range hood up under cabinet and determine final
   location by centering beneath cabinet. Mark on the  
 
  underside of cabinet the location of the 4 keyhole mounting  
  slots on the range hood. Set range hood aside on a covered  
 surface.
■  
Depending on your installation, remove either top or rear 
rectangular vent knockout. If using round vent, remove 
top rectangular knockout.
■  
Make sure damper pivot is nearest to top/back edge of 
range hood.
■  
Remove tape from damper flap.
 
NOTE: The exhaust adaptor/damper can be installed up
 
to 1" (2.5 cm) on either side of the hood center to
 
accommodate off-center ductwork.
■  
If using rectangular vent, attach rectangular damper/
vent connectors to the range hood using sheet metal 
screws.
 
NOTE: If the wall cap is directly behind the vent
 
connector, the dampers in the connector and wall cap
 
must not interfere with each other. Remove the vent
 
connector damper if they interfere.
■  
If using round vent, attach vent transition piece
 
(purchased separately) to range hood top using sheet
 
metal screws.
A. Vertical vent
B. Sheet metal screws
C. Hinge pin
D. Vent knockouts
E. Horizontal vent
A. Keyhole slot
3.  Use 
1
8
" (3 mm) drill bit and drill 4 pilot holes as shown.
A. Drill pilot hole.
4.  Install the 4 - 4.5 mm x 13 mm mounting screws in pilot
   holes. Leave about 
1
4
" (6.4 cm) space between screw heads
   and cabinet to slide range hood into place.
5.  Run the home power supply cable according to the National
   Electric Code or CSA standards and local codes and
   ordinances. There must be enough wiring from the fused
   disconnect (or circuit breaker) box to make the connection in
   the hood electrical terminal box.
  
NOTE: Do not reconnect power until the installation is
  
complete.
6.  Remove the screws from the terminal box cover. Then slide
   the cover toward the outside edge of range hood to position
   the large end of the keyhole slots over the mounting tabs.
A. Screws
B. Mounting tabs
C. Terminal box cover
A
B
C
B
A
B
C
D
C
E
A
A
¹⁄₄
"