Tripp Lite PDU3VSR3L1520 User Manual

Page of 4
 
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model #: PDU3VSR3L1520
3-Phase Switched PDU, 5.7 kW, 24 208V outlets (21-C13, 3-C19) 3-ft. Cord, NEMA L15-20P 20A input connection
 
Highlights
Switched 5.7kW 3 Phase 208V PDU; 70 in. / 178cm 0U vertical rackmount
Reports voltage, frequency & load per-outlet or phase via ethernet interface
Visual current meter; Toolless button-mount installation
NEMA L15-20P 20A (3P+E) 208V 3 phase input; 3 ft. / 1m line cord
21 C13 & 3 C19 single phase switched outlets with cord retention brackets
Temperature, humidity and contact closure monitoring options
Description
 Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle
or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption per-phase or
per-receptacle. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP,
Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom
programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent
inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of
unauthorized hardware. PDU output current consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely
via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip. 
Applications
Ideal for 3 phase network configurations in datacenters and heavily configured equipment racks
Package Includes
Switched rackmount PDU with pre-installed mounting buttons
Cord retention brackets
Rack mounting brackets
Owner's manual
Features
5.7kW 3 phase 208V Switched Power Distribution Unit / PDU with built-in web/network interface
Attached NEMA L15-20P 20A (3P+E) 208V 3 phase input; 3 ft. / 1m cord
0U, 70 inch / 178cm vertical form factor 
24 switched 208V outlets (21 C13, 3 C19) in 3 single phase load banks
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage, per-outlet and per-phase load levels
Digital display with scroll-buttons supports per-outlet or per-phase load levels, IP-address self-identification and 180 degree display rotation
Supports user-specified alarm notification thresholds
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4
optional SRSWITCH door sensors
DHCP/Manual configuration support
10/100 Mbps auto-sensing 
Real-time clock backup maintains the time of day and date even if the PDU is unpowered