KitchenAid 30" Wall-Mount Canopy Hood Installation Guide

Page of 28
8
5. Remove terminal box cover.
6. Remove the knockout in the range hood back cover and 
install a UL listed or CSA approved ½" strain relief with the 
strain relief clamping screws on the inside of the terminal box.
Install Range Hood
Vented Installations
1. Install damper on top of the exhaust opening. Check that the 
damper opens freely.
2. Go to “Mount the Range Hood” in this section.
Non-vented (recirculating) Installations
NOTE: Recirculating Kit Part Number W10272172 is required. 
See the “Assistance or Service” section to order.
1. Install the non-vented (recirculating) diverter supplied with the 
recirculating kit.
2. Fit the diverter over the vent motor exhaust outlet and push 
down to seat on outlet. Check that the diverter exhaust 
outlets are parallel with the vent motor sides so that they will 
align with the vent cover openings in the lower chimney.
3. Install the charcoal filters included with the recirculating kit. 
See the “Range Hood Care” section.
Mount the Range Hood
1. Using 2 or more people, lift the range hood and place the 
mounting hood brackets over the mounting screws. 
2. Run the home power supply cable (black, white and green 
wires) through the strain relief in the back of the range hood 
and into the terminal box.
3. Push the range hood into its mounted position. The ½" strain 
relief should fit into the 1¼" diameter hole when the range 
hood is seated into position.
4. Securely tighten the mounting screws.
Make Electrical Connection
1. Disconnect power.
2. Use UL listed wire connectors and connect black wires (B) 
together.
3. Use UL listed wire connectors and connect white wires (D) 
together. 
A. Diverter
B. Vent canopy
A
B
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
range hood.
Failure to do so can result in back or other injury.
A. Home power supply cable
B. Black wires
C. UL listed wire connectors
D. White wires
E. Green (or bare) ground wire from home 
power supply connected to green ground 
screw
F. Range hood power supply cable
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F