KitchenAid 24-Inch 6-Cycle/7-Option Dishwasher, Pocket Handle Installation Guide

Page of 56
13
Remove the ground connector screw and place through the ring 
terminal of the green ground wire. Reattach and tighten the 
ground connector screw.
NOTE: Do not pre-twist stranded wire. Twist on wire connector. 
Gently tug on wires to be sure both are secured.
Connect wires black to black and white to white, using UL Listed/
CSA Approved twist-on wire connectors (included with power 
supply cord kit).
If needed, see website for animated representation of this step. 
Visit www.kitchenaid.com/electrical under FAQ tab.
Tighten strain relief screws to secure cord.
Place wires inside terminal box. Insert tabs on left side of cover. 
Make sure wires are tucked inside box. Close cover ensuring 
wires are not pinched. Use 
¹⁄₄" hex-head socket, nut driver or 
Torx
®
 T20
®
 screwdriver and previously removed screw to secure 
cover.
NOTE: Do not plug into outlet until instructed to do so. 
WARNING
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector in 
terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.