Xerox Document Workstation with PlotWorks Support & Software User Guide

Page of 700
Chapter 11-4 • PlotWorks User Guide
Setting up GFI Folders 
XEROX WIDE FORMAT 510dp, 8825, 8850, 8830, and 8855 
This section only applies if you are running the XEROX WIDE FORMAT 510dp, 
8830, 8825, 8850, or 8855 folder/printers with the GFI option. If you are not 
running this configuration, skip this section and move to the next subsection.
GFI (Generic Finisher Interface) is the proprietary communication protocol used 
with XEROX WIDE FORMAT printers and finishing devices. PlotWorks GFI 
support requires creating a Folder Description File (FPF file) for the attached 
folder. Depending upon your hardware configuration follow the instructions 
below to create the FPF file. 
You may have created the FPF file while connecting the PlotWorks Folder Cable. 
In this case you do not have to recreate it unless your hardware configuration has 
changed.
XEROX WIDE FORMAT 8825 using the AccXES Controller
This section only applies if you are running the XEROX WIDE FORMAT 8825, 
folder/printer, with the GFI option, and are using the AccXES controller. If you 
are not running this configuration, skip this section and move to the next 
subsection.
1.
Install the printer and folder as illustrated in the diagram below. Note that the 
PlotWorks Folder Cable, the serial cable provided by PLP is not used here.
Fig 11.1 
PlotWorks, 
AccXES 
and GFI 
folder 
connection 
2.
Using the AccXES WebPMT or Configuration sheet verify that the AccXES 
Controller is successfully connected to the folder.
3.
Open the PlotWorks Printer Interface for the printer that is connected to the 
GFI folder.